Compaq TL891 - DLT Tape Library User Manual page 135

User guide
Table of Contents

Advertisement

Table 6-2
Fault Symptom Codes
FSC
1001
1002
1003
1004
1005
1006
1007
1008
1009
1020
1021
1022
1023
1024
Compaq Confidential – Need to Know Required
Writer: Everett Godaire Project: TL891 MiniLibrary System User's Guide Comments:
Part Number: ER-TL891-UA.A01 File Name: g-ch6 Diagnostics and Troubleshooting Last Saved On: 3/3/99 11:54 AM
continued
Message
SCSI Firmware Error
SCSI FIFO Empty
SCSI FIFO Error
SCSI Gross Error
Illegal SCSI Cnt Cmd
SCSI Message Error
SCSI Invalid Element
SCSI No Pending Int
SCSI Invalid Int
No Active Command
SCSI Invalid Request
SCSI Invalid Semaphore
SCSI Invalid State
SCSI Invalid Ctl Msg
Diagnostics and Troubleshooting 6-7
Description
While getting SCSI command bytes,
the SCSI chip reported an empty FIFO
before it was expected.
While getting SCSI command bytes,
the SCSI chip reported that the FIFO
was not empty when it should be
empty.
Gross error status was returned by the
SCSI chip. This usually means that the
SCSI chip is in an illegal state.
The SCSI chip rejected a command
from the firmware.
Not reported
Firmware error
An interrupt was returned from the
SCSI chip when one was not expected.
An invalid interrupt was returned from
the SCSI chip.
Status was returned from the control
process when no command was
active.
An invalid request was received from
the control process (firmware error).
Firmware Error
Firmware Error
A message sent from the control
process was not valid.
continued

Advertisement