Porttest - Brocade Communications Systems Brocade 8/12c Command Reference Manual

Brocade fabric os command reference manual supporting fabric os v6.4.0 (53-1001764-01, march 2010)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

portTest

Performs a functional test of a switch in a live fabric.
Synopsis
porttest [-ports itemlist][-iteration count][-userdelay time][-timeout time][-pattern pattern]
[-patsize size][-seed seed][-listtype porttype]
Description
Use this command to isolate problems in a single replaceable element and to trace problems to
near-end terminal equipment, far-end terminal equipment, or the transmission line. You can
perform this test on a daily basis or as needed to verify the persistence of failures detected earlier.
This command verifies the functional operation of the switch by sending frames from a port's
transmitter, and looping the frames back through an external fiber cable into the port's receiver.
The test exercises all switch components from the main board, to the fibre cable, to the media (of
the devices and the switch), and back to the main board.
The cables and media connected should be of the same type: a short-wavelength media (switch)
port should be connected to another short-wavelength media (device) port using a
short-wavelength cable; a long-wavelength port should be connected to a long-wavelength port,
and a copper port should be connected to a copper port.
Only one frame is transmitted and received at any given time. The port LEDs flicker green while the
test is running.
This command supports E_Ports, F_Ports (must support ELS Echo), L_Port, and N->N loopback
ports. In addition, on switches running Fabric OS v6.4.0 and later, you can now use portTest on
port configurations that previously caused nonspecific test results or were skipped by portTest. The
following ports are now support the portTest diagnostics.
This command is currently not supported on the following ports or switch configurations:
This command performs the following operations:
1. Initiates tests on certain ports (portTest command).
2. Stops active tests on certain ports (stopPortTest command).
3. Takes a snapshot of the test result (portTestShow command).
Use the stopPortTest command to stop the test. Refer to the stopPortTest help page for more
information.
Fabric OS Command Reference
53-1001764-01
Ports with index numbers greater than 255.
Ports with swapped areas.
Ports in shared area regions.
Ports in logical switches.
Ports in Base Switches.
Long Distance ports.
Interchassis links (ICL) ports
F_Ports connected to an Access Gateway
EX_Ports
E_Ports connected to EX_Ports
The portTest diagnostics is not supported in Access Gateway mode.
2
portTest
799

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v6.4.0

Table of Contents