Wwnaddress - Brocade Communications Systems Brocade 8/12c Command Reference Manual

Brocade fabric os command reference manual supporting fabric os v6.4.0 (53-1001764-01, march 2010)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

2

wwnAddress

wwnAddress
Binds an FC Port ID to a device WWN.
Synopsis
wwnaddress --bind [WWN] [PID]
wwnaddress --unbind [WWN]
wwnaddress --show
wwnaddress --findPID [WWN]
wwnaddress --help
Description
Use this command to manage address assignments for a given device world wide name. The
allocation of a PID to a specified device WWN supports the persistence of the PID based on the
WWN of the device to which the PID is bound. If the PID is not bound to a device WWN, the device
can get the same or a different PID irrespective of which port it logs in to a given switch partition.
This command fails under any of the following conditions:
The command provides a --show option that displays the currently bound address for all WWNs.
Alternately, you can use the --findPID option to display the PID currently bound to a specified
WWN.
Notes
Dynamic Area Mode and WWN-Based persistent PID must be enabled on the switch before you can
assign an address with this command. Refer to configure for more information.
This command is supported only on the Brocade DCX and on the DCX-4S.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands
This command has the following operands:
--bind
--unbind
--show
1006
The PID is currently bound to another port through port address binding. Use portaddress
--unbind to free up the PID.
The WWN is already bound with a different PID, or the PID is bound to another WWN. Use
wwnaddress --unbind to remove the PID-WWN binding.
There is no space left in the WWN-PID table for an additional entry. Use wwnaddress --unbind
to free up space in the table.
Assigns the lower two bytes of the Fibre Channel address to the specified
WWN.
WWN
Specifies the WWN for the device to which the PID should be assigned.
PID
Specifies the PID (the lower 16 bits of the address excluding the domain part)
in hexadecimal format to be bound to the device WWN. Note that only the
upper 10 bits of the PID can be used for a unique route. Therefore, not all
addresses in the 16-bit range are available.
Removes the WWN-PID binding corresponding to the specified device WWN.
WWN
Specifies the WWN for the device from which to remove the PID binding.
Displays all WWN-PID entries currently present in the partition.
Fabric OS Command Reference
53-1001764-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v6.4.0

Table of Contents