Polycom RealPresence Collaboration Server (RMX) 1500 Hardware Guide
ISDN/PSTN Clock Source
Each RTM ISDN 1500 has its own primary and secondary clock source. The first span to
synchronize becomes the primary clock source and the second span to synchronize becomes
the secondary clock source. This clock is used to synchronize ISDN spans only (it is not the
system clock).
A single clock source triggers an alarm that can be turned off by setting the appropriate flag
in the system configuration.
RealPresence Collaboration Server (RMX) 1500 Power Supply
Subject to availability on the RMX 1500 there are two types of power supplies (Power-One &
Astec), both are identical in their functionality.
Power Supply LEDs
On the RMX 1500 there are three LEDs that indicate the power status.
Table 1-8
Power Supply LED
OK
AC/~ (symbol)
1-18
RMX 1500 Power Supply LEDs
Description
DC power indication to internal components of the RMX:
Green - DC Power Good.
Power supply failure Indication:
Amber - Power Supply Failure.
(Alarm symbol)
Main power supply indication (Voltage In):
Green - Voltage Input > 85 VAC.
Polycom, Inc.
Need help?
Do you have a question about the RMX 1500 and is the answer not in the manual?
Questions and answers