14.0

Multiplex Zone Addressing Guide

Before installing a multiplex device, its address and other
information must be programmed into the control panel. (To disable
or remove a multiplex point, set the program address for 00 [see
Section 10.4]).
If using a DS7436 Multiplex Expansion Module,
programming must be done using bus "A."
Perform the following:
• Program the control panel.
- Refer to sections 10.2-10.5, Zone Programming.
These sections allow you to define the Multiplex Zone's
address (zone number), its type (single or multiple zone input
device, a DS7465, a Multiplex Smoke or a Multiplex Smoke
with a Low Temperature Alarm), which zone or output function
it will follow (1-24) and its partition (1-8).
For example:Program zone 9 to be a single zone input device
(MX950 ) that follows zone function 1 and is in
partition 1.
Procedure: Enter the programmer's mode.
Enter address 0039.
Enter the data digits as [0] and [1] followed by the
[#] button.
Enter address 0291.
Enter the data digits as [0] and [0] followed by the
[#] button.
Exit the programmer's mode.
• Program the BusLoc
®
feature.
At this point, you must decide whether or not to use the BusLoc
feature.
BusLoc
®
is a proprietary method of tying the multiplex zones to
the control panel to prevent the system from being taken over.
Using BusLoc
®
will program an invisible identification code into
the multiplex zones.
NOTE:
If using the DS7432 8-Input Remote Module or the DS7433
8-Input Direct Module, the BusLoc
used.
- If you choose to use the BusLoc
code at programming address 9999.
It is very important to save this code under lock and key. If
you need to replace the control panel, you will have to program
it with the same BusLoc
multiplex devices will not match codes with the new control
panel.
For example:Program the BusLoc
Procedure: Enter the programmer's mode.
Enter address 9999.
Enter the data digits as [5], [4], [3], [2], and [1]
followed by the [#] button.
Exit the programmer's mode.
Once the pre-programming is done, you are ready to program the
multiplex devices. Perform the following:
• Disconnect all multiplex devices from the DS7430.
• Program the multiplex devices through the control panel. Per-
form the following:
- Enter the programmer's mode.
- Enter the multiplex programming mode.
Do this by entering [9] [9] [9] [5] followed by the [#] button.
Page 86
P/N: F01U035325-01
®
feature can not be
®
feature, program a 5-digit
®
code as the previous panel or the
®
code to be 54321.
Copyright © 2007 Bosch Security Systems, Inc.
- The control will then take a few seconds to check the multiplex
connection to confirm nothing is connected to it. The display
will show the following:
- The display will then call-up the first zone you have pre-
programmed to be a multiplex zone. To access a different
zone, press the [Reset/*] key, then enter the three digit value of
the zone you want. The display will show the following:
Before you do anything else, reconnect the multiplex device (that
coincides with the displayed zone) to the multiplex bus of the
DS7430.
For DS7465s and Multiple Input devices, pressing the [#] button
now will program these devices to the control panel. Remember,
these devices take up two addresses. When address 009 (for
example) is a DS7465, pressing the [#] button now will program
both addresses 009 and 010.
For Single Input devices, press the [#] button to continue
programming. The display asks whether you are programming a
sensor or a contact; it will show the following:
If you are programming a sensor, press the [4] button to program
®
these devices to the control panel. If you are programming a contact,
press the [6] button to program these devices to the control panel.
- If the device is successfully programmed, the keypad will
sound a single beep and increment to the next zone (if there is
one) pre-programmed as a multiplex zone.
Disconnect the device you just programmed and
connect the next device (that belongs to the displayed
zone) to the multiplex bus of the DS7430 and press
the [#] button. Continue programming.
24-hour zones will alarm when you exit the
programmer's mode. Alarm reports for these zones
will be sent if they have been programmed. If you do
not want these reports sent, disconnect power from
the system now by unplugging the transformer and
removing the red battery lead. Do not reconnect power
until all zones have been installed and connected to
the multiplex bus.
- If no other zones have been pre-programmed, the display will
show the following:
- You may now exit the Zone Programmer's mode by pressing
the [*/Reset] button for 2 seconds. This brings you back to the
Programmer's Mode. To exit the Programmer's Mode, press
the [*/Reset] button for 2 seconds.
- If the zone is unsuccessfully programmed, the keypad will
sound a three-beep error tone.