The Master Keypad

7.6.1 General Information

Your system may include a Master keypad. A Master keypad is a
DS7447/DS7447E keypad programmed to give a user access to
all the partitions the user has access to, not just the partition in
which the Master keypad is located. This is different from a
Standard keypad in that Standard keypads only give access to the
single partition in which they are located. Commands entered at
the Master keypad will affect all the partitions to which the user has
access. If this is not desirable, the Master keypad can also be
used to control each partition individually; this is called Single
Partition Mode. Single Partition Mode allows a user to control any
or all of the partitions the user has access to on an individual (one-
by-one) basis (see section 7.6.3 for more information on Single
Partition Mode).
NOTE:
In order to use the Master keypad, your PIN must be
assigned to the partition in which the Master keypad is
located.

7.6.2 Master Keypad Displays

Master keypad displays will differ slightly from Standard keypads.
The Master keypad display will scroll the Status of each partition,
followed by the partition number. For example, if all partitions are
armed, the Master keypad will scroll through the following displays:
Armed
Armed
Armed
Armed
area 1
area 2
area 3
area 4
If only partitions 1, 2, 3, 4, 6, and 8 are armed, the Master keypad
will scroll through the following displays:
Armed
Armed
Armed
Armed
area 1
area 2
area 3
area 4
Displays for partitions that are Not Ready will display in the same
manner.
The chart at the bottom of this page will help you understand what
each LED function of the Master keypad represents.

7.6.3 Single Partition Mode

Single Partition Mode is used to control partitions on a "one at a
time/one by one" basis from the Master keypad.
To enter the Single Partition Mode, enter your [PIN], then press the
[#] key twice. This will call up the first partition you have access to.
Enter the command sequence you wish for this partition. You do
not need to use your PIN again. To move on to the next partition you
have access to, press the [#] key twice.
To exit the Single Partition Mode, hold the [*] key down for 2 seconds.
The system will also automatically drop out of Single Partition
Mode after 40 seconds without a keypad entry.
Example of accessing Single Partition Mode
• Enter your [PIN], followed by the [#] key twice: [1] [2] [3] [4] [#] [#].
LED
Armed
All partitions are disarmed.
(red)
Status
Not ready to arm (if the Armed LED is
(green)
On, all partitions are armed).
Power
The Control Panel has lost all power;
(green)
Fire
There are no fire alarms.
(red)
DS7400Xi ( 4+) Reference Guide
Armed
Armed
Armed
area 5
area 6
area 7
Ready to Arm
Armed
Ready to Arm
area 5
area 6
area 7
Off
no AC or battery.
Copyright © 2007 Bosch Security Systems, Inc.
• The first partition you have access to will be displayed: "Ready
to Arm. Cafeteria."
• Complete the command sequence (in this case arming) you
wish for this partition: [#] [On].
• Move to the next partition you have access to by pressing the [#]
key twice: [#] [#].
• The next partition you have access to will be displayed: "Ready
to Arm. Office."
• Complete the command sequence you wish for this partition.
• After you have completed all the command sequences for the
partitions you have access to, exit Single Partition Mode by
pressing the [*] key for two seconds.

7.6.4 Arming from the Master Keypad

To arm all the Partitions to which you have access:
• [PIN] + any Arming Command Sequence. This will arm all the
partitions to which you have access even if they are already
armed.
To arm only some of the Partitions to which you have access:
• [PIN] + [#] + [#]. This puts you into Single Partition Mode.
• The first partition to which you have access is displayed: "Ready
to Arm. Cafeteria."
• Enter the Arming Command Sequence you want for this parti-
tion.
• [#] + [#] opens the next partition to which you have access.
• The next partition to which you have access is displayed: "Ready
to Arm. Office."
Armed
• Enter the Arming Command Sequence you want for this parti-
area 8
tion.
• After arming any or all partitions to which you have access, you
may exit Single Partition Mode by holding the [*] key for at least
Armed
two seconds. The system will also drop out of Single Partition
area 8
Mode after 40 seconds without a keypad entry.

7.6.5 Disarming from the Master Keypad

To disarm all the Partitions to which you have access:

• [PIN] + [Off]. This will disarm all the partitions to which you have
access even if they are already disarmed.
To disarm only some of the Partitions to which you have access:
• [PIN] + [#] + [#]. This puts you into Single Partition Mode.
• The first partition to which you have access is displayed: "Armed.
Cafeteria."
• If you wish to disarm this partition, enter [Off]. If not, go to the next
step.
• [#] + [#] opens the next partition to which you have access.
• The next partition to which you have access is displayed: "Armed.
Office."
• If you wish to disarm this partition, enter [Off]. If not, go to the next
step.
• After disarming any or all partitions to which you have access,
you may exit Single Partition Mode by holding the [*] key for at
Flashing
One or more partitions are armed, or
an alarm has occurred.
One or more zones are bypassed.
Control Panel problems exist.
See Error Displays.
A fire zone is in alarm.
On
All Partitions are armed, and no
alarms have occurred.
All partitions are ready to arm.
Normal Operation.
The Control Panel is running on AC
power with no problems,
A fire trouble condition exists.
P/N: F01U035325-01
Page 29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds7445Ds7445iDs7447Ds7447e

Table of Contents