How To Program The Control Panel; Entering The Programmer's Mode; Reading Back A Program Address; Entering A Value In A Program Address - Bosch DS7400Xi Reference Manual

Control/communicator ver. 4+
Hide thumbs Also See for DS7400Xi:
Table of Contents

Advertisement

8.0

How to Program the Control Panel

8.1

Entering the Programmer's Mode

To enter the Programmer's Mode, enter the Programmer's Code followed by [#] [0]. Shorting the program pads (see section 2.0 for
location) on the control panel will also activate Programmer's Mode.
NOTE:
The factory set default Programmer's Code is [9] [8] [7] [6]. If the system has been reprogrammed for 6-digit PINs, the default
Programmer's Code will be [9] [8] [7] [6] [5] [4].
8.2

Reading Back a Program Address

Once you are in the programmer's mode, to read back the value of a Program Address, enter that Program Address followed by [#]. Each
data digit is displayed one data digit at a time. To view the second data digit, enter the # button again.
The display will look like this:
8.3

Entering a Value in a Program Address

To enter a value in the Program Address, enter the Program Address, then enter the value for each Data Digit, then enter [#] to save it and
move on to the next Program Address. Entering data digit 1 will increment you to the next data digit.
The display will show the Program Address and will display the value of each Data Digit after you enter it. The data will be programmed
(saved) when you press the [#] key. The control panel will automatically increment to the next program address.
• If you wish to program that next address, enter the necessary information.
• If you wish to read back the value of that address, press the [#] key.
• If you wish to program a different address, press the [*] key two times and enter the program address you wish to program.
If you make a mistake at any time, press the [*] key two times (before pressing the [#] key). This will clear the display, allowing you to enter
the program address you wish to work with.
8.4

HEX values

Some Data Digit values will be higher than 9. These values must be programmed by pressing the [*] key followed by some other
number. These values will display as HEX characters (A - F) when entered. Example: entering *0 at the keypad will display an A.
The HEX character values are as follows:
*0 = A
*1 = B
*2 = C
*3 = D
8.5

Defaults

The DS7400Xi is shipped from the factory as a working, pre-programmed control. Many of the programming addresses may already be
set to the values you need. The default values are shown in
If the value you would like is in
In the example, a "0" is the default value:
If the default value is not shown in
8.6

Setting the Control to the Factory Default

Only enter [0] [1] [#] in Program Address 4058 when you are completely sure you want to erase all installer program-
ming. Entering [0] [1] [#] in Program Address 4058 will immediately reset the control to the factory default. Any
programming already done by the installer will be erased. This action cannot be reversed.
To set the control's programming values back to the default, enter the programming mode, then enter [4][0][5][8][0] [1] [#].
8.7

Exiting the Programmer's Mode

To exit the Programmer's Mode, press the [*] key for a minimum of 2 seconds. If no keypad entries are made for 4 minutes, the control
will automatically exit you from the Programmer's Mode.
Page 32
P/N: F01U035325-01
*4 = E
*5 = F
, you don't need to re-program this address.
Reverse Print
, it will be shown in a separate table.
Reverse Print
Copyright © 2007 Bosch Security Systems, Inc.
.
Reverse Print
DS7400Xi (4+) Reference Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds7445Ds7445iDs7447Ds7447e

Table of Contents