LED Command Center D621
User's Guide

Advertisement

Table of Contents
loading

Summary of Contents for Bosch D621

  • Page 1 LED Command Center D621 User’s Guide...
  • Page 2 EFORE ECURITY YSTEM IS CONNECTED TO TELEPHONE NUMBER ____________________________________ ECURITY ONTROL ANEL IS CONNECTED TO THE PHONE JACK LOCATED ____________________________________ : _________________________________ RANSFORMER OCATION : _______________________________ IRCUIT REAKER UMBER D621 User’s Guide 46840D Page 2 © 2003 Bosch Security Systems...
  • Page 3: Table Of Contents

    Change Others’ Passcode Level (Cmd 56) ............25 Add a Passcode (Cmd 56) ..................... 26 Delete a Passcode (Cmd 58) ..................27 Renew One-Time Passcodes (Cmd 53) ..............28 D621 User’s Guide © 2003 Bosch Security Systems Page 3 46840D...
  • Page 4 Table 7: Trouble Points ....................32 Table 8: System Test Lights ..................33 Table 9: System Test Point Status ................. 34 Table 10: Watch Tones ....................37 Table 11: Watch Tone Description ................. 38 D621 User’s Guide 46840D Page 4 © 2003 Bosch Security Systems...
  • Page 5: About This User's Guide

    Status & Cmd Indicators Indicators Point Status Status 9 10 11 12 13 14 15 16 Part Check Change Watch Areas Test System Weekly Sounder Figure 1: Command Center D621 User’s Guide © 2003 Bosch Security Systems Page 5 46840D...
  • Page 6: Security System Basics

    • Fire Points: Only monitor fire detection devices, such as smoke detectors. They are always on and cannot be turned off. • Non-Fire Points: Always on and cannot be turned off. D621 User’s Guide 46840D Page 6 © 2003 Bosch Security Systems...
  • Page 7: All On

    Check with your security company to learn which points are Part points. Controlled Points are Part On KITCHEN ROOM ROOM DINING LIVING BEDROOM ROOM Figure 3: Part On D621 User’s Guide © 2003 Bosch Security Systems Page 7 46840D...
  • Page 8: Command Center Keys

    To activate the special function, press the key twice (consecutively) within 2 seconds. Your security company labels each key to its assigned function. Table 1: Command Center Keys D621 User’s Guide 46840D Page 8 © 2003 Bosch Security Systems...
  • Page 9: Command Center Tones

    Command Center emits a tone to alert you when any watched point is faulted. The tone varies in duration, depending on the selected Watched Tone. (See Select Watch Tone.) Table 2: Command Center Tones D621 User’s Guide © 2003 Bosch Security Systems Page 9 46840D...
  • Page 10: Command Center Led Descriptions

    • Fire Alarms (highest priority) • Burglary Alarms • Fire Troubles • Non-Fire Troubles (lowest priority) Events grouped as highest priority are always sent to the central station first. D621 User’s Guide 46840D Page 10 © 2003 Bosch Security Systems...
  • Page 11: Fire Alarms

    When a trouble event such as a low battery condition occurs, your Command Center emits a Trouble tone. The Command Center Status indicator is on steady. See Check System Troubles for more information on determining the nature of the trouble. D621 User’s Guide © 2003 Bosch Security Systems Page 11 46840D...
  • Page 12: How Your System Reports Alarms

    To adjust the Command Center sounder volume, press and hold the [*] key and then press [1] to increase the volume or [4] to decrease the volume. Press [CMD] to exit this command function when all adjustments are made. D621 User’s Guide 46840D Page 12 © 2003 Bosch Security Systems...
  • Page 13: Log Out Of The System

    9 10 11 12 13 14 15 16 Enter your passcode to turn the system off. Once the system is off, the Command Center turns the All On indicator or the Part On indicator off. D621 User’s Guide © 2003 Bosch Security Systems Page 13 46840D...
  • Page 14: Turn The System All On (All On Or Cmd 1)

    The system then turns All On. The All On indicator remains on steady. To turn the system off, enter your passcode. D621 User’s Guide 46840D Page 14 © 2003 Bosch Security Systems...
  • Page 15: Turn The System Part On (Part On Or Cmd 2)

    The system then turns All On. The All On indicator remains on steady. Status Part 9 10 11 12 13 14 15 16 To turn the system off, enter your passcode. D621 User’s Guide © 2003 Bosch Security Systems Page 15 46840D...
  • Page 16: Turn The System Part 2 On (Cmd 3)

    The system then turns All On. The All On indicator remains on steady. Status Part 9 10 11 12 13 14 15 16 To turn the system off, enter your passcode. D621 User’s Guide 46840D Page 16 © 2003 Bosch Security Systems...
  • Page 17: Set Part 2 Points (Cmd 65)

    Yes or No for Part 2 Mode (Yes = Active, ready to detect intrusion; No = Non-Active, you can move freely without sounding an alarm). Status Part 9 10 11 12 13 14 15 16 Press [CMD] to exit this command. D621 User’s Guide © 2003 Bosch Security Systems Page 17 46840D...
  • Page 18: Turn The System On With No Delay

    Press [NO DELAY] to turn the system on with no delay. There is a 10-sec. window before the panel arms as No Delay. To turn the system off, enter your passcode. D621 User’s Guide 46840D Page 18 © 2003 Bosch Security Systems...
  • Page 19: Turn The System On With No Exit Tone

    Exit Delay period. • Part 2 On (Cmd 3) Operation: “Part” and “Cmd” LEDs are on during the Exit Delay period. The Cmd indicator turns off when Exit Delay expires. D621 User’s Guide © 2003 Bosch Security Systems Page 19 46840D...
  • Page 20: Turn The System On With Points Faulted (Force Arm)

    If a point becomes faulted after the exit delay begins, the Command Center displays the faulted point. If the point remains faulted at the end of exit delay, it starts an alarm event. D621 User’s Guide 46840D Page 20 © 2003 Bosch Security Systems...
  • Page 21: Bypass Points

    9 10 11 12 13 14 15 16 Bypassed points flash on the Command Center. To un-bypass a point, repeat the steps above for the desired point number. Press [CMD] to exit this command. D621 User’s Guide © 2003 Bosch Security Systems Page 21 46840D...
  • Page 22: Date And Time (Cmd 45)

    Then, it alerts you to enter the IMPORTANT current time and date. D621 User’s Guide 46840D Page 22 © 2003 Bosch Security Systems...
  • Page 23: Change A Passcode (Cmd 55)

    If the error tone sounds, try a different new passcode. Enter your new passcode again. The Command Center sounds the OK tone and returns to the off state. You successfully changed your passcode. D621 User’s Guide © 2003 Bosch Security Systems Page 23 46840D...
  • Page 24: Change Others' Passcodes (Cmd 56)

    Enter the new passcode again for verification. Press [CMD]. The available user numbers flash. Repeat Steps 5 and 6 to change another user passcode, or press [CMD] twice to exit. D621 User’s Guide 46840D Page 24 © 2003 Bosch Security Systems...
  • Page 25: Change Others' Passcode Level (Cmd 56)

    If the user does not exist in the system, the Command Center will emit an error tone. IMPORTANT Enter the new authority level (1 to 4) followed by [CMD]. The available user numbers flash. Select another user, or press [CMD] twice to exit. D621 User’s Guide © 2003 Bosch Security Systems Page 25 46840D...
  • Page 26: Add A Passcode (Cmd 56)

    11. Enter the new passcode again for verification. Press [CMD] twice. Point indicators 1 to 3 flash. 12. Press [2] to assign a passcode authority level to the new user. D621 User’s Guide 46840D Page 26 © 2003 Bosch Security Systems...
  • Page 27: Delete A Passcode (Cmd 58)

    If the user does not exist in the system as set up by your security company, the Command Center emits an error tone. IMPORTANT Press [CMD] to exit this command. D621 User’s Guide © 2003 Bosch Security Systems Page 27 46840D...
  • Page 28: Renew One-Time Passcodes (Cmd 53)

    [*] key. (For example, press [5] [*] to renew passcode 5.) Press [CMD] to exit this command. D621 User’s Guide 46840D Page 28 © 2003 Bosch Security Systems...
  • Page 29: Check System Troubles (Cmd 4)

    The trouble tone for AC Failure events sounds at all command centers in all areas. However, the trouble tone must be silenced in each area (silencing it in one area does not silence it in the other areas). IMPORTANT D621 User’s Guide © 2003 Bosch Security Systems Page 29 46840D...
  • Page 30: View Alarm Memory (Cmd 40)

    If the point indicator is flashing slow, the alarm was aborted. No reports for the alarm event were sent to the security company. The LED Command Center only displays Points 1 to 16. IMPORTANT D621 User’s Guide 46840D Page 30 © 2003 Bosch Security Systems...
  • Page 31: View System Trouble (Cmd 42)

    Data Bus Device Trouble/Reset System Fault Flashing Slow Service Interval Flashing Fast Ground Fault Condition Table 6: System Trouble Events Press [CMD] twice to exit the View System Trouble command. D621 User’s Guide © 2003 Bosch Security Systems Page 31 46840D...
  • Page 32: View Point Trouble (Cmd 48)

    No Point Trouble Wiring Fault Flashing Slow RF Sensor Low Battery Flashing Fast RF Sensor Missing Table 7: Trouble Points Press [CMD] twice to exit the View Point Trouble command. D621 User’s Guide 46840D Page 32 © 2003 Bosch Security Systems...
  • Page 33: System Test (Cmd 41)

    When testing the bell and strobe, check for bell/strobe activation. The LED testing status does not indicate bell/strobe test failure (point indicator does not flash fast upon test failure). IMPORTANT D621 User’s Guide © 2003 Bosch Security Systems Page 33 46840D...
  • Page 34: Walk Test (Cmd 44)

    Walk Test is over when the Status indicator stops flashing. Test fire detection devices (smoke/heat detectors) weekly as instructed by your security company and in accordance with the devices instructions. IMPORTANT D621 User’s Guide 46840D Page 34 © 2003 Bosch Security Systems...
  • Page 35: Reset The System (Cmd 47)

    Cmd indicator. Enter your passcode if necessary. The system now resets. After the system resets, the Command Center automatically exits this command. D621 User’s Guide © 2003 Bosch Security Systems Page 35 46840D...
  • Page 36: Turn Watch On/Off (Cmd 61)

    If Watch Tone is ON, the LED indicator for Point 2 flashes. Press [2] to turn off. • If Watch Tone is OFF, the LED indicator for Point 1 flashes. Press [1] to turn on). D621 User’s Guide 46840D Page 36 © 2003 Bosch Security Systems...
  • Page 37: Select Watch Tone (Cmd 62)

    Beep Until Key Beep Until Closed Table 10: Watch Tones If you just want to review (not change) the current watch tone setting, press [CMD] to exit this function. D621 User’s Guide © 2003 Bosch Security Systems Page 37 46840D...
  • Page 38: Table 11: Watch Tone Description

    After making your selection, the display confirms the choice you made by displaying the corresponding point on the Command Center before exiting this command. The selected point indicator turns on solid. D621 User’s Guide 46840D Page 38 © 2003 Bosch Security Systems...
  • Page 39: Select Watch Points (Cmd 63)

    [*] key. (For example, press [5] [*] to turn Watch off for Point 5.) Status Part 9 10 11 12 13 14 15 16 Press [CMD] to exit this command. D621 User’s Guide © 2003 Bosch Security Systems Page 39 46840D...
  • Page 40: Extend Auto On Time (Cmd 51)

    These indicators are: • Point 1 Indicator = Area 1 • Point 2 Indicator = Area 2 • Point 3 Indicator = Area 3 • Point 4 Indicator = Area 4 D621 User’s Guide 46840D Page 40 © 2003 Bosch Security Systems...
  • Page 41: All Areas Off (Cmd 81)

    Point Indicator 1 On Solid: Auto-Forward ON (Point Indicator 2 flashes) • Point Indicator 2 On Solid: Auto-Forward OFF (Point Indicator 1 flashes) Press [CMD] to exit this command. D621 User’s Guide © 2003 Bosch Security Systems Page 41 46840D...
  • Page 42: Remote Arming With Telephone, Area 1

    Enter your passcode. The Command Center emits a single-beep tone, indicating the remote programming session has begun. When the session is completed, the Command Center automatically exits this command. D621 User’s Guide 46840D Page 42 © 2003 Bosch Security Systems...
  • Page 43: Security System Limitations

    Although having a security system may make you eligible for reduced insurance premiums, the system is no substitute for insurance. Warning devices cannot compensate you for loss of life or property. D621 User’s Guide © 2003 Bosch Security Systems Page 43 46840D...
  • Page 44: Fire Safety And Evacuation

    Locate smoke detectors between = Smoke Detector sleeping areas and family living Bedroom areas. A smoke detector should be located on each story including basements, but excluding crawl spaces and unfinished attics. D621 User’s Guide 46840D Page 44 © 2003 Bosch Security Systems...
  • Page 45: Maintenance And Service

    If your Command Center gets dirty, apply a household glass cleaner to a clean cloth or paper towel and wipe the surface. Do not spray any liquid directly onto the Command Center. It could run inside the case and damage electrical circuits. D621 User’s Guide © 2003 Bosch Security Systems Page 45 46840D...
  • Page 46: Glossary

    Faulted Point Point that is not normal, such as an open door or window. Warble tone that is on for 1 sec. and then briefly off Fire Alarm Tone (repeatedly). D621 User’s Guide 46840D Page 46 © 2003 Bosch Security Systems...
  • Page 47 Warble tone that is on briefly, followed by a pause, and Trouble Tone then followed by the warble tone (repeatedly). Tone that is on for 1 sec., then briefly off. Warble Tone D621 User’s Guide © 2003 Bosch Security Systems Page 47 46840D...