Bosch DIP-3040-00N Installation Manual

Divar ip 3000 series
Hide thumbs Also See for DIP-3040-00N:

Advertisement

DIVAR IP 3000
DIP-3040-00N, DIP-3042-2HD, DIP-3042-4HD
en
Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch DIP-3040-00N

  • Page 1 DIVAR IP 3000 DIP-3040-00N, DIP-3042-2HD, DIP-3042-4HD Installation Manual...
  • Page 3: Table Of Contents

    Installing a hard drive System setup - first steps Introduction Setup instruction Starting the application Using Bosch VMS Configuration Wizard Using Bosch VMS Configuration Client Using Bosch VMS Operator Client Recovering the unit Additional Documentation and client software Bosch Sicherheitssysteme GmbH Installation Manual 2013.09 | V2 | DOC...
  • Page 4: Safety Precautions

    Handle used batteries carefully. Do not damage the battery in any way. A damaged battery may release hazardous materials into the environment. Dispose of empty batteries according to the manufacturer's instructions. 2013.09 | V2 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
  • Page 5: Electrical Safety Precautions

    Installation should only be carried out by qualified customer service personnel in accordance with the applicable electrical regulations. Disposal Your Bosch product has been developed and manufactured using high- quality materials and components that can be reused. This symbol means that electronic and electrical devices that have reached the end of their working life must be disposed of separately from household waste.
  • Page 6: Esd Precautions

    Do not discard a used battery in the garbage or a public landfill. Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly. 2013.09 | V2 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
  • Page 7: System Overview

    Simply connect to the network and turn on the unit — DIVAR IP 3000 is ready to begin recording straight out of the box. Bosch Video Management System manages all IP and digital video and audio, plus all the security data being transmitted across your IP network. It seamlessly combines IP cameras and encoders, provides system-wide event and alarm management, system health monitoring, user and priority management.
  • Page 8: Power Supply

    Front view: Lock for front cover LAN activity LED Power on/off LED System status LED Hard disk access LED Individual hard disk LED 2013.09 | V2 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
  • Page 9: Led Description - Front Panel

    LED description - front panel This chapter describes the LED displays on the front of the chassis. LED indicator LED color LED state Description Power LED Power off Blue On (default) Working (S0 state) Bosch Sicherheitssysteme GmbH Installation Manual 2013.09 | V2 | DOC...
  • Page 10: Lan Port Led Description - Rear Panel

    System has booted in normal operation. Blue Blinking System is booting or shutting down Critical event occurred, such as degraded RAID volume. Bosch also provides the API and then application program is able to control this status. Individual hard Off (default) Hard drive not present.
  • Page 11: Chassis Setup And Maintenance

    Notice! We recommend using the respective Bosch hard disk drives. The hard disk drives as one of the critical component are carefully selected by Bosch based on available failure rates. HDD – not delivered from Bosch – are not supported. Information on supported HDDs can be found in the datasheet in the Bosch Online Product Catalog.
  • Page 12: System Setup - First Steps

    The Microsoft Software License Terms and the EULA (End User License Agreement) are displayed. Accept the license terms, then click Start. Windows restarts. After restart is finished, press CTR+ALT+DELETE. The Windows logon page is displayed. Enter the default password WSS4Bosch. 2013.09 | V2 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
  • Page 13: Using Bosch Vms Configuration Wizard

    IP, you can use the Configuration Wizard. In all other cases we recommend using the Bosch VMS Configuration Client. Notice! To perform administrative tasks, the BVRAdmin account can be entered when Bosch VMS default screen is displayed. To do so, press CTRL+ALT+DEL, then hold down SHIFT while clicking the Switch User option.
  • Page 14 – all advanced configurations beyond a basic setup (maps or alarms, for example) For these tasks refer to the Bosch VMS manual (see Additional Documentation and client software, page 27): To achieve a quick configuration using the Configuration Wizard: On the Bosch VMS default screen, double-click the Bosch VMS Wizard icon.
  • Page 15 If a DHCP server is employed in the network for the dynamic assignment of IP addresses, activate acceptance of IP addresses automatically assigned to the device. Certain applications (VRM, Bosch Video Management System, Bosch Video Client, Configuration Manager) use the IP address for the unique assignment of the device. If using...
  • Page 16 | System setup - first steps DIVAR IP 3000 Time settings page You configure the time settings of the operating system. 2013.09 | V2 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
  • Page 17 System setup - first steps | en Video settings page This page displays the devices and services that are included in the latest saved configuration. You can import a configuration. Bosch Sicherheitssysteme GmbH Installation Manual 2013.09 | V2 | DOC...
  • Page 18 Device selection page This page displays all video devices that are not included in the latest saved configuration. Deselect the devices that should not be added to the configuration, then click Next. 2013.09 | V2 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
  • Page 19 Client must be used in order to set or change device passwords. Password check is performed automatically, when you do not enter a character in a password field for a few seconds or you click outside the password field. Bosch Sicherheitssysteme GmbH Installation Manual 2013.09 | V2 | DOC...
  • Page 20 Before selecting a recording profile observe the following: – Recording profile details All video devices use the default recording profile details. To change these use the Bosch VMS Configuration Client. – Stream quality settings All video devices use the default settings for Stream 1 to record.
  • Page 21 The Night schedule is active from 6 p.m. until 8 a.m., Monday through Friday. The Weekend schedule is active 24 hours a day for Saturday and Sunday. To change the schedule use the Bosch VMS Configuration Client. Bosch Sicherheitssysteme GmbH Installation Manual 2013.09 | V2 | DOC...
  • Page 22 Notice! If the wizard stops and the message appears, that the internal iSCSI storage is not ready for recording because the LUNs are not formatted, you must format the LUNs using Bosch VMS Configuration Client. To format the LUNs, see Bosch VMS Configuration Manual, Chapter Formatting a LUN.
  • Page 23 DIVAR IP 3000 System setup - first steps | en User accounts page You can add users and passwords. Use Configuration Client to add user groups and to change permissions. Bosch Sicherheitssysteme GmbH Installation Manual 2013.09 | V2 | DOC...
  • Page 24: Using Bosch Vms Configuration Client

    If the IP addresses of devices that should be added do not fall within the same IP range as the DIVAR IP, we recommend using the Bosch VMS Configuration Client. To assign device IP addresses: On the Bosch VMS default screen, double-click the Configuration Client icon change device network settings. The application starts. Enter the following, then click OK.
  • Page 25: Using Bosch Vms Operator Client

    DIVAR IP 3000 System setup - first steps | en To perform further functionalities refer to the Bosch VMS manual. References to the manual are described in Additional Documentation and client software, page 27. Using Bosch VMS Operator Client Use Bosch VMS Operator Client to verify the live, recording and playback functionality of DIVAR IP.
  • Page 26: Recovering The Unit

    After the restart of the unit, the factory default settings are installed and the Windows logon screen is displayed. The factory default settings are: – IP address: 192.168.0.200 – Subnet mask: 255.255.255.0 – User: BVRAdmin – Password: WSS4Bosch 2013.09 | V2 | DOC Installation Manual Bosch Sicherheitssysteme GmbH...
  • Page 27: Additional Documentation And Client Software

    Additional Documentation and client software | en Additional Documentation and client software Documentation for Bosch Security System products can be found as follows: www.boschsecurity.com > select your region and your country > select Product Catalog > start a search for your product > select the product in the search results to show the existing documents.