Hardware Layout Example - Bosch DS7400Xi Reference Manual

Control/communicator ver. 4+
Hide thumbs Also See for DS7400Xi:
Table of Contents

Advertisement

4.0

Hardware Layout Example

Keypads #11 - #15 must be connected to
the Options Bus. Keypads #1 - #10 must
be connected to the Keypad Bus.
Armed
Arme d
St atus
Stat us
Power
Powe r
Fire
Fire
On
Off
1
2
3
1
Per imete r
4
5
6
O n ly
4
No
7
8
9
7
Entry
Byp ass
*
0
#
*
Syste m
Reset
Armed
St atus
Arme d
Armed
Pe ri met er
Perimete r
Power
Sta tus
St atus
Superv isory
Supe rvis ory
Fire
Power
B e ll Silenc ed
Bell Sile nce d
Pow er
Fire
Troubl e
Fire
Trouble
On
Off
1
2
3
1
1
4
5
6
Per imete r
O n ly
4
4
No
7
8
9
Entry
7
7
Byp ass
*
0
#
*
*
Syste m
Reset
Armed
Arme d
Pe ri met er
Armed
Perimete r
St atus
Sta tus
St atus
Superv isory
Supe rvis ory
Power
Power
B e ll Silenc ed
Fire
Pow er
Bell Sile nce d
Fire
Trouble
Troubl e
Fire
On
Off
1
2
3
1
1
Per imete r
4
5
6
O n ly
4
4
No
7
8
9
Entry
7
7
0
#
Byp ass
*
*
*
Syste m
Reset
Armed
Armed
Perimete r
Arme d
Pe ri met er
St atus
St atus
Supe rvis ory
Sta tus
Superv isory
Power
Power
B e ll Silenc ed
Pow er
Bell Sile nce d
Fire
Fire
Troubl e
Fire
Trouble
On
Off
1
2
3
1
1
Per imete r
4
5
6
O n ly
4
4
No
7
8
9
7
Entry
7
Byp ass
*
0
#
*
*
Syste m
Reset
DS7447/DS7447E and DS7445/DS7445i
Keypads
• Up to 15 keypads may be used. Keypads #1 - #10 connect to the Keypad Bus and keypads #11 - #15
connect to the Option Bus. One keypad must be designated as keypad #1 and connected to the Keypad
Bus. See the DS7447/DS7447E, DS7445/DS7445i, and DS7448 Installation Instructions for further details.
• A DS7420i (Dual Phone Line/Bell Supervision Module) may be connected to the Control Panel, and
placed within the enclosure. Connect to the Options Bus of the control panel. See the DS7420i Installation
Instructions for further details.
• Up to 2 DS7488s (Octal Relay Modules) may be connected to the Control Panel, and placed within the
enclosure. Connect to the Options Bus of the Control Panel. This provides an additional 8 Form "C"
relay outputs for the Control Panel. See the DS7488 Installation Instructions for further details.
• A DS7430 or a DS7436 (Multiplex Expansion Module) may be connected to the control panel via the
expansion port. This will allow for the connection of additional zones via the Options Bus. See the DS7430
or DS7436 Installation Instructions for further details.
• Up to 30 DS7432s (8-Input Remote Modules) may be connected to the DS7430 or DS7436. Connect to the
Power and Bus Terminals of the Multiplex Expansion Module. This allows for a means of addressing up to
240 input loops of conventional contacts to the Control Panel. See the DS7432 Installation Instructions for
further details.
• Up to 2 RF3222 (120-Zone Wireless Receivers) may be connected to the DS7430 or DS7436. Connect to
the Power and Bus terminals of the Multiplex Expansion Module. This allows for the monitoring of wireless
detectors.
• A DS7416i Advanced Radio Communications Module may be connected to the Control Panel via the Options
Bus. This allows for connection to a radio network.
• Up to 248 zones are available for the connection of Single, Multiple, Input/Output, and Multiplex devices.
Up to 112 wireless zones (137-248) are also available.
DS7400Xi ( 4+) Reference Guide
DS7416i
Communications
Module
R
B
G
Y
On
Off
2
3
Per imete r
5
6
O nly
No
8
9
Entr y
Byp ass
0
#
Sys tem
Reset
1
R
2
B
Option
Bu s
3
G
1 2 3 4 5 6 7 8
1 2 3
4 5
6 7
8
®
4
Y
9 10 11 12 13 14 15 16
5
+
Batte ry
TEST WEEKLY
On
On
6
7
+
Bell Outp ut
Off
8
2
2
3
3
Off
+
9
Au xiliary
Pe r i m eter
Per imete r
Out put
5
5
6
6
O n ly
10
O nly
No
No
8
8
9
9
Ent ry
+
+
Ent ry
Bypass
0
0
#
#
Byp a s s
1 12 1 3 1 4 15 16 17 18 1 9 20 21 22 23 24 25 2 6 27 28
System
R e set
Syst e m
Re set
DS7420i Dual Phone
Line/Bell Supervision
1 2 3
4 5
6 7
8
1 2 3 4 5 6 7 8
®
9 10 11 12 13 14 15 16
TEST WEEKLY
Module
On
On
2
3
Off
Off
2
3
Pe r i m eter
Per imete r
5
6
5
6
O nly
O n ly
8
9
No
No
8
9
Ent ry
Ent ry
0
0
#
#
Bypass
Byp a s s
System
Syst e m
Re set
R e set
Battery
1 2 3 4 5 6 7 8
®
1 2 3
4 5
6 7
8
9 10 11 12 13 14 15 16
TEST WEEKLY
On
On
Off
Off
2
2
3
3
Pe r i m eter
5
6
Per imete r
O n ly
5
6
O nly
No
8
9
No
8
9
Ent ry
Ent ry
Bypass
0
#
0
#
Byp a s s
System
Syst e m
R e set
Re set
Note: Ensure at least 1/4" separation
between battery wires and all
other cabling.
Wireless Sensors
Copyright © 2007 Bosch Security Systems, Inc.
DS7430
+
+
Power Bus
DS7400Xi
+ – –
R
R
T
T
R R
T T
R
R T
T
DS7488 Octal
Relay Board
Battery
+ – + –1
+ – + –1
2 3
4 5
6 7
8
2 3
POWER BUS
POWER BUS
+ – + –1
2 3
4 5
6 7
8
+ – + – 1
2 3
POWER BUS
POWER BUS
DS7432 8-Input
Remote Modules
Dry contact inputs
+
1 2 3
4 5
1 2 3
-
2 G 1
+
NO
C NC
BUS
DS7450/52 Series Contacts, DS7460 Input Modules,
DS7465 Input/Output Modules, MX540, MX775,
MX794, MX835, MX934, MX938, and MX950 motion
detectors and MX280 Series Smoke Detectors
RF3222 120-Zone
Wireless Receivers
P/N: F01U035325-01
4 5
6 7
8
4 5
6 7
8
47k
EOL
Page 11