10.0

Programming

10.1
General Control Programing: Program Address (0000)
General Control programming defines the system-wide general operating parameters. See Glossary (section 6.1) for further details.
Normal Arming Custom Arming Perimeter Instant Arming Perimeter Arming Maximum Security Arming Closing Ring Back Siren on Communication Fail Restore Swinger Shunts
Select Options
Allow Normal and Custom Arming**
Allow Perimeter Instant Arming**
Allow Perimeter Arming**
Allow Maximum Security Arming**
Closing Ring-Back
Siren on Comm. Fail for Silent Zone
50 Hz. operation
60 Hz. operation
= For installations in North America, select 60 Hz. operation.
*0 - *5 are Hex values. They will display as A - F at the keypads.
Restore zone when Sounders Silence
Restore zone when Zone Restores
Restore zone when System is Disarmed
Allow Swinger Shunts. Send Bypass Reports
Allow Swinger Shunts. No Bypass Reports
** =
• Normal Arming = [PIN] + [On]: If programmed, Normal Arming arms the entire system while allowing entry delays for entry/
exit zones.
• Perimeter Instant Arming = [PIN] + [No Entry] + [Perimeter Only]: If programmed, Perimeter Instant Arming arms only the
perimeter of the system and does not allow entry delays for entry/exit zones.
• Perimeter Arming = [PIN] + [Perimeter Only]: If programmed, Perimeter Arming arms only the perimeter of the system
while allowing entry delays for entry/exit zones.
• Custom Arming = [PIN] + [#] [4]: If programmed, Custom Arming allows custom arming of the system and bypasses the
zone functions specified in data addresses 2725-2728.
• Maximum Security Arming = [PIN] + [No Entry] + [On]: If programmed, Maximum Security Arming arms the entire system
and does not allow entry delays for entry/exit zones.
Page 34
P/N: F01U035325-01
0
1 2 3 4 5 6 7
Select Options
Copyright © 2007 Bosch Security Systems, Inc.
Enter the Data Digit as a:
8 9 *0 *1 *2 *3 *4 *5
Enter DD as a:
0 1 2
4
5
6 7 8
3
DS7400Xi (4+) Reference Guide
Data Digit
1
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds7445Ds7445iDs7447Ds7447e

Table of Contents