10.6
Zone Bypass Programming: Program Addresses (2721-2724)
Zone Bypass programming determines which zone functions can be bypassed. Zone functions that can not be bypassed can not be
force armed either. Fire zones can never be manually bypassed, but can be force armed. The Default of [0] or [8] means those zones can
be bypassed.
Note: This programming item does not affect Custom Arming Programming (PA 2725-2778) or
Swinger Shunt Bypasses (see programming for Program Address 0000).
Select Options
Zone Function 1 Can Be Bypassed
Zone Function 2 Can Be Bypassed
Zone Function 3 Can Be Bypassed
Zone Function 4 Can Be Bypassed
Select Options
Zone Function 5 Can Be Bypassed
Zone Function 6 Can Be Bypassed
Zone Function 7 Can Be Bypassed
Zone Function 8 Can Be Bypassed
Select Options
Zone Function 9 Can Be Bypassed
Zone Function 10 Can Be Bypassed
Zone Function 11 Can Be Bypassed
Zone Function 12 Can Be Bypassed
Select Options
Zone Function 13 Can Be Bypassed
Zone Function 14 Can Be Bypassed
Zone Function 15 Can Be Bypassed
Zone Function 16 Can Be Bypassed
DS7400Xi ( 4+) Reference Guide
0
1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
*0 - *5 are Hex values. They will display as A - F at the keypads.
0
*0 - *5 are Hex values. They will display as A - F at the keypads.
0
1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
*0 - *5 are Hex values. They will display as A - F at the keypads.
0
*0 - *5 are Hex values. They will display as A - F at the keypads.
Copyright © 2007 Bosch Security Systems, Inc.
Enter the Data Digit as a:
Enter the Data Digit as a:
1 2 3 4 5 6 7
Enter the Data Digit as a:
Enter the Data Digit as a:
1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
8
9 *0 *1 *2 *3 *4 *5
P/N: F01U035325-01
PA 2721
Data Digit
1
2
PA 2722
Data Digit
1
2