Download Print this page

Module Addressing; Installation - Bosch CM728B Installer's Reference Manual

Fingerprint reader modules

Advertisement

Module Addressing

Each reader fitted to the system must be assigned a
unique address on the LAN using the on board rotary
address switch. The following table shows the address
setting for each reader as well as the number of keypad,
reader devices each panel can support.
Figure 2: Address Switch
Module Address Setting
Address No Keypad No
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Table 2: Address Table
Only 1 reader can be assigned to each address.
i
All modules are supplied from the factory set to
Note
address 1. You must power cycle the panel or
perform a LAN scan whenever you change the
module address.

Installation

The reader should be installed onto a solid surface using
suitable mounting fixtures. Wiring should only be
performed while the control panel is powered off.
1) Using the 1:1 mounting template supplied, mark
out the location of the 2 mounting holes and the
cable exit hole before drilling out all points as
necessary.
Bosch Security Systems
06/12 CM728B-CM729BIRG FTR1.0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
CM728B-CM729B Installer Reference Guide
CM728B & CM729B Mounting Template
Scale 1:1
6 x 4.0mm
(1/8") holes
Tamper Switch
Do Not Create A Hole
In This Location
Connection Cable
Entry Point
48.0mm
CM728B & CM729B Mounting Template.ai
Figure 3: Mounting Template (Not to Scale)
2) If the reader is to occupy an address on the LAN
other than address 1, you will need set the required
address before mounting. Each reader on the
system must have a unique address. See Table 2:
for more information.
3) Once the address has been set, terminate the
required wires referring to the Connection Diagram
on page 7. Unused wires should be insulated to
prevent short circuits.
4) If using the on board lock output to open the door,
you must make sure to use a relay and protection
diode as shown.
5) Once the wiring is complete, mount the reader to
the wall and fit the cover plate using the M3 x 6mm
hex screws.
Rev 1
3

Advertisement

loading

This manual is also suitable for: