3. Locate the SNMP v3 Informs section. Select Add New SNMP v3 User to reveal its configuration section.
AMP users will need to configure all v3 users that are configured on the controller; the SNMP Inform receiver
in the AMP will be restarted when users are changed or added to the controller.
Username - Username of the SNMP v3 user as configured on the controller.
Auth Protocol - Can be MD5 or SHA. The default setting is SHA.
Auth and Priv Passphrases - Enter the auth and priv passphrases for the user as configured on the
controller.
Priv Protocol - Can be DES or AES. The default setting is DES.
4. Locate the Telnet/SSH Settings section, and complete or adjust the default value for the field.
shows the setting and default value.
Table 28 Device Setup > Communication > Telnet/SSH Settings Fields and Default Values
Setting
Telnet/SSH Timeout
(3-120 sec)
5. Locate the HTTP Discovery Settings section and adjust the default value.
default value.
Table 29 Device Setup > Communication > HTTP Discovery Settings Fields and Default Values
Setting
HTTP Timeout
(3-120 sec)
6. Locate the ICMP Settings section and adjust the default value as required.
default value.
Table 30 Device Setup > Communication > ICMP Settings Fields and Default Values
Setting
Attempt to ping
devices that
were
unreachable
via SNMP
7. Locate the Symbol 4131 and Cisco Aironet IOS SNMP Initialization area. Select one of the options listed.
Table 31
Table 31 Device Setup > Communication > Symbol 4131 and Cisco Aironet IOS SNMP Initialization Fields and Default Values
Setting
Do Not Modify
SNMP Settings
Enable read-write
SNMP
54 | Configuring AMP
Default Description
10
Sets the timeout period in seconds used when performing Telnet and SSH commands.
Default
Description
5
Sets the timeout period in seconds used when running an HTTP discovery scan.
Default
Description
Yes
When Yes is selected, AirWave attempts to ping the AP device.
Select No if performance is affected in negative fashion by this function. If a large number
of APs are unreachable by ICMP, likely to occur where there is in excess of 100 APs, the
timeouts start to impede network performance.
NOTE: If ICMP is disabled on the network, select No to avoid the performance penalty caused
by numerous ping requests.
describes the settings and default values:
Default Description
Yes
When selected, specifies that AirWave not modify any SNMP settings. If SNMP is not already
initialized on the Symbol, Nomadix, and Cisco IOS APs, AirWave is not able to manage them.
No
When selected, and when on networks where the Symbol, Nomadix, and Cisco IOS APs do
not have SNMP initialized, this setting enables SNMP so the devices can be managed by
AirWave.
Table 29
shows the setting and
Table 30
shows the setting and