APPENDIX 3 FIRMWARE SWITCHS (WSW)
Selector
No.
1
2
3
4
5
6
7
8
l
Selectors 1 and 2: Dial pulse generation mode
These selectors set the number of pulses to be generated in pulse dialing.
N:
N + 1: Dialing "N" generates "N + 1" pulses.
10 - N: Dialing "N" generates "10 - N" pulses.
l
Selectors 3 and 4: Break time length in pulse dialing
These selectors set the break time length in pulse dialing.
(Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.)
l
Selectors 5 and 6: Inter-digit pause
These selectors set the inter-digit pause in pulse dialing.
(Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.)
WSW01 (Dial pulse setting)
Function
Dial pulse generation mode
Break time length in pulse dialing
Inter-digit pause
Switching between pulse (DP) and
tone (PB) dialing, by the function
switch
Default dialing mode, pulse (DP) or
tone (PB) dialing
Dialing "N" generates "N" pulses. (Dialing "0" generates 10 pulses.)
Setting and Specifications
No. 1 2
0 0
0 1
1 0
1 1
No. 3 4
0 0
0 1
1 0
1 1
No. 5 6
0 0
0 1
1 0
1 1
0: Yes
0: PB
A-8
:
N
:
N+1
:
10-N
:
N
:
60 ms
:
67 ms
:
40 ms (for 16 PPS)
:
64 ms (at 106-ms intervals)
:
800 ms
:
850 ms
:
950 ms
:
600 ms
1:
No
1:
DP