MFC-8440/8840D/8840DN, DCP-8040/8045D/8045DN
SERVICE MANUAL
3.26
High-voltage PS PCB ASSY
(1) Remove the bind B M4x12 Taptite screw, and then remove the high-voltage PS PCB
ASSY.
(2) Disconnect the flat cable from the high-voltage PS PCB ASSY.
Taptite, bind B M4x12
High-voltage PS PCB ASSY
Flat cable
Fig. 4-122
4-69