Replacing A Hot-Swap Redundant Power Supply - Lenovo ThinkServer TS430 User Manual

Machine type: 0387, 0388, 0389, 0390, 0391, 0392, 0393 and 0441
Hide thumbs Also See for ThinkServer TS430:
Table of Contents

Advertisement

10. Install the new power supply assembly into the chassis so that the four screw holes in the new power
supply assembly are aligned with the corresponding holes marked with A in the rear of the chassis.
Then, install the four screws
Note: Use only screws provided by Lenovo.
Figure 87. Installing the non-hot-swap power supply assembly
11. Refer to your note and connect the new power supply assembly cables to the system board, all drives,
and or hot-swap hard disk drive backplane(s), depending on the model. Then, properly route the cables
and secure the cables with the cable clips and ties in the chassis.
12. Reinstall the front system fan(s). See "Replacing the front system fan" on page 157.
13. If you are instructed to return the old non-hot-swap power supply assembly, follow all packaging
instructions and use any packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the replacement, go to "Completing the parts replacement" on page 170.

Replacing a hot-swap redundant power supply

Attention: Do not open your server or attempt any repair before reading and understanding the "Safety information"
on page iii and "Guidelines" on page 85.
148
ThinkServer TS430 User Guide
1
to secure the new power supply assembly in place.

Advertisement

Table of Contents
loading

Table of Contents