Installing The Serveraid-Br10I Sas/Sata Controller - Lenovo ThinkServer TD200 Installation And User Manual

(english) installation and user guide
Hide thumbs Also See for ThinkServer TD200:
Table of Contents

Advertisement

5. Disconnect any cables connected to the adapter.
6. Carefully open the retaining clip on each end of the ServeRAID-BR10i adapter
7. If you are instructed to return the adapter, follow all packaging instructions, and

Installing the ServeRAID-BR10i SAS/SATA controller

The ServeRAID-BR10i SAS/SATA controller must be installed in the dedicated
connector, PCI slot 1, on the system board. The ServeRAID-BR10i adapter is
supported on hot-swap server models only. The ServeRAID-BR10i SAS/SATA
adapter enables integrated RAID levels 0, 1, and 1E capability on hot-swap hard
disk drives.
Attention:
updates. If the device is part of a cluster solution, verify that the latest level of code
is supported for the cluster solution before you update the code.
To install the ServeRAID-BR10i adapter, do the following:
106
ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide
Attention:
To avoid breaking the retaining clips or damaging the
ServeRAID-BR10i adapter connector, open and close the clips gently.
connector and remove the adapter from the server.
use any packaging materials that are supplied to you for shipping.
Some cluster solutions require specific code levels or coordinated code
1. Read the safety information (see "Safety" on page vii and "Installation
guidelines" on page 37).
2. Turn off the server and peripheral devices, and disconnect the power cords
and all external cables. Remove the side cover (see "Removing the side cover"
on page 43).
Attention:
To avoid breaking the retaining clips or damaging the
ServeRAID-BR10i adapter connector, open and close the clips gently.
3. Carefully position the server on its side so that it is lying flat and facing up.
Note: Do not allow the server to fall over.
4. Rotate the rear adapter-retention bracket to the open (unlocked) position.
5. Open the retaining clip on each end of the ServeRAID-BR10i adapter
connector on the system board.
6. Touch the static-protective package containing the ServeRAID-BR10i adapter
to any unpainted metal surface on the server. Then, remove the
ServeRAID-BR10i adapter from the package.
7. Turn the ServeRAID-BR10i adapter so that the ServeRAID-BR10i adapter keys
align correctly with the connector.
Attention:
Incomplete insertion might cause damage to the system board or
the ServeRAID-BR10i adapter.

Advertisement

Table of Contents
loading

Table of Contents