v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the Hardware Maintenance Manual to determine which components are customer replaceable units
(CRUs) and which components are field replaceable units (FRUs).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
0068002
CMOS battery cleared.
2011001
PCI-X PERR
2018001
PCI Express uncorrected or uncorrected error 1. Reseat all affected adapters.
182
ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide
Action
1. Reseat the battery.
2. Clear the CMOS memory.
3. Replace the following components one at a time,
in the following order, restarting the server after
each one:
a. Battery
b. (Trained service technician only) System
board.
1. Reseat all affected adapters.
2. Update the PCI adapter firmware.
3. Remove the adapter.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Adapter
b. (Trained service technician only) System
board
2. Update the PCI adapter firmware.
3. Remove the adapter.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Adapter
b. (Trained service technician only) System
board