2F3/2F4-5
(4) Detaching and refitting the primary transfer cleaning unit
Procedure
1. Remove the primary transfer unit (See page
1-6-16).
2. Pull out the primary transfer cleaning unit
from the main unit frame a little with under-
neath the right
.
3. Pull out the waste toner outlet
the left side of the primary transfer cleaning
unit from the main unit frame.
4. Remove the primary transfer cleaning unit.
5. Check or replace the primary transfer clean-
ing unit and then refit all the removed parts.
1-6-24
which is on
Primary transfer
cleaning unit
Figure 1-6-35