Replacing 3.5-Inch Hard Disk Drive; How To Locate Failed Disks - NEC Express5800 Series User Manual

Express5800 series;
Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

REPLACING 3.5-INCH HARD DISK DRIVE

Follow the procedure below to remove the failed hard disk. If the hard disk fails, it should
be replaced with new device with the server powered-on.

How to Locate Failed Disks

This section describes a procedure to locate failed disks.
1.
Open [Data Viewer] from ESMPRO Manager.
If trouble occurs, the color changes from green to red.
In this case, you will notice that there is trouble with both the SCSI Enclosures
(ID: 41) and (ID: 42).
2.
Check the SCSI Enclosures (ID: 41) and (ID: 42) on the tree.
See the path information in [General Information] of [SCSI Slot] to locate a
group of 3.5-inch hard disk drive bays that corresponds to each enclosure.
The table below shows the path information on Groups 1 and 2:
Slot
Group1
Group2
PCI module
SCSI adapter
10
5
11
5
Linux Setup and Operation 3-3
SCSI bus
0
0

Advertisement