7-6 Troubleshooting
On-screen error message
0B83 BMC IBF or OBF
check
failed
0B8A BMC SEL area full
0B8B BMC progress check
timeout
0B8C BMC command
access failed
0B8D Could not redirect the
console - BMC Busy
0B8E Could not redirect the
console - BMC Error
0B8F Could not redirect the
console – BMC
parameter Error -
0B90 BMC Platform
Information Area
corrupted
0B91 BMC update firmware
corrupted
0B92 Internal Use Area of
BMC FRU corrupted
0B93 BMC SDR Repository
empty
0B94 IPMB signal lines do
not respond
0B95 BMC FRU device
failure
0B96 BMC SDR Repository
failure
0B97 BMC SEL device
failure
0B98 BMC RAM test error
0B99 BMC Fatal hardware
error
0B9A BMC not responding
0B9B Private I2C bus not
responding
Cause
RMC device is faulty.
There is no space to write
system event logs.
BMC check is suspended.
BMC command access failed.
Console cannot be redirected
(BMC is busy).
BMC is faulty.
Configuration is faulty.
BMC device is faulty.
Data within SROM is faulty.
SDR data is faulty.
SMC is faulty.
NVRAM within BMC is faulty.
SDR repository within BMC is
faulty.
SEL repository within BMC is
faulty.
BMC RAM is faulty.
BMC FPGA is faulty.
BMC device is faulty.
I2C bus is faulty.
Action
Replace the CPU/IO module or ft
Remote Management Card
(option).
Clear system event logs after
saving them.
Replace the CPU/IO module or ft
Remote Management Card
(option).
Replace the CPU/IO module or ft
Remote Management Card
(option).
There is a possibility that the
BMC was busy and could not
respond. Restart the server
again.
Replace the CPU/IO module or ft
Remote Management Card
(option).
Configure the console redirection
by using BIOS setup.
Replace the CPU/IO module or ft
Remote Management Card
(option).
If updating SDR does not help,
replace the CPU/IO module or ft
Remote Management Card
(option).
Replace the CPU/IO module or a
center plane after determining
where IPMB error has occurred
based on OS information.
Replace the CPU/IO module or ft
Remote Management Card
(option).
If updating FPGA does not help,
replace the CPU/IO module or ft
Remote Management Card
(option).
Replace the CPU/IO module or ft
Remote Management Card
(option).
Replace the part related to failed
I2C bus.