On-screen error message
9058 - 905F
9062 - 9063
9065
9071 - 9072
9080 - 908F
9080 - 9085
9087 - 908F
9086
9026
Cause
This CPU/IO module detected
the mismatch of CPUID
between the CPU/IO
modules.
CPU/IO module or ft Remote
Management Card (option) is
faulty.
One or both the CPU/IO
modules have a problem.
Water-cooling kit has leaked
out.
This CPU/IO module failed to
get the information from
another CPU/IO module.
The CPU/IO modules were
unsuccessful to share
information.
The chip set revisions are
mismatched.
Troubleshooting 7-11
Action
CPU configuration may be
different between the CPU/IO
modules.
Replace the CPU.
If this does not help, replace the
CPU/IO module.
If turning AC power off and on
does not help, replace the
CPU/IO module or ft Remote
Management Card (option).
There are some error messages
in addition to this error code.
Check the other error message.
Replace the water-cooling kit.
If this does not help, replace the
CPU/IO module.
When the system is running in
the duplex mode, it is no
problem.
If the system cannot be running
in the duplex mode due to
continuous this error, replace the
CPU/IO module.
If this does not help, replace
another CPU/IO module or
center plane.
The GA driver may not support
the server. Confirm that the driver
is an appropriate one and restart
the server.
If this does not help, replace the
CPU/IO module or center plane.
The model of the CPU/IO
modules mounted to the CPU
modules is different. Replace the
CPU/IO modules with those of
the same model.