Event/History Log - Visonic Remote Programmer Software User Manual

For powermax and powermaster
Table of Contents

Advertisement

Condition
COMMUNICATION
FAILURE
TAMPER OPEN
JAMMED
TROUBLE
TAMPER ALARM
OTHERS
PROTOCOL
VERSION
6.20 Event/History Log  
The Event Log displays the different events that the control panel has detected,
together with their details. The Remote Programmer stores up to 100 events. This
table includes: event number; relevant zone or user number/code; relevant zone
name; type of event; date and time.
The History Log displays up to 1000 different events that the control panel has
detected and stored in a different folder.
Available in PowerMax only: Performing Full Upload will automatically load the Event Log.

Available in PowerMax+ only:
 When communicating at the speed of 9600 bps (via serial or GSM digital communication), the Remote
Programmer loads all the data.
 When communicating at the speed of 300 bps (via PSTN or GSM analog communication), you need to perform
Upload Table to load the data.
DE5450S Remote Programmer Guide Rev. 8
Description
disconnected.
Communication failure between the control panel
and the monitoring station.
Control panel has been opened or tampered
with.
Control panel transmissions are being jammed.
Control panel has been opened or tampered
with. The alarm. The alarm state ends only after
disarming and then rearming the system.
Other system faults.
System's communication protocol version.