Chapter 7: Connecting to the Control Panel

7.1.3 Callback

In the Phone number field the user enters the Remote Programmer return
telephone number (the telephone number that connects to the modem). In the
Wait before sending field, the user enters the amount of time (in seconds) the
Remote Programmer waits before identifying the call as failed.

7.2 Connecting to PowerMax/PowerMaster

The login procedure enables Remote Programmer to transfer information to and
from the control panel and can be initiated either when creating a new site file or
when a site file is already open. This procedure differs when the communications
mode is set to Serial Port or Telephone Modem. The first part of the procedure is
the same for both types of communication modes:
Caution:
Local Connection - In order to successfully complete the login process, check
that:
 The PowerMax/PowerMaster control panel is set to the Installer mode (not
applicable to PowerMax+).
 The communication port is defined correctly.
 You enter the correct download code.
To Login when creating a new site file
1.
Select New Site from the Sites menu,
Or
Click New in the Sites window.
2.
In the New Site dialog box, fill in the fields (the fields will be
enabled/disabled according to the communication mode.).
3.
Click Login.
52
Figure 7-7: Callback Phone Number String
DE5450S Remote Programmer Guide Rev. 8