Toshiba Strata CIX Programming Manual page 84

Telephone button programming manual
Hide thumbs Also See for Strata CIX:
Table of Contents

Advertisement

Telephone Button Programming
500 Series Programs
Table 1-35
Programs 500~577 (continued)
Button
Sequence
513-04
Abandoned Call
Record Output
FB04
Hold
, n,
513-05
Display Transferred
Call Records
FB05
Hold
, n,
514
SMDR for OLG
Assignment
514
Hold
,
514-00
OLG
Hold
n,
514-01
SMDR Record
Display
FB02
Hold
, n,
514-02
Outgoing Records
FB03
Hold
, n,
514-03
Outgoing Records
FB03
Hold
, n,
515
View BIOU Control
Relay Assignment
515
Hold
,
515-00
BIOU (1 or 2)
Hold
n,
515-01
BIOU Relay 1 or 5
FB01
Hold
, n,
515-02
BIOU Relay 2 or 6
FB02
Hold
, n,
515-03
BIOU Relay 3 or 7
FB03
Hold
, n,
515-04
BIOU Relay 4 or 8
FB04
Hold
, n,
1-80
Value(s)
n =
1. Enable
2. Disable (default)
n =
1. Source (default)
2. Destination
Hold
,
n =
1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
n =
1. Enable (default)
2. Disable
n =
1. Enable (default)
2. Disable
Hold
,
n =
1. Source (default)
2. Destination
Hold
,
n =
1 or 2
n =
1. Not Use (default)
2. Ext Paging
3. Night Bell
4. Night Relay
5. Door Lock
Hold
,
Summary
Enable record generation for abandoned calls. Incoming SMDR must
be turned on. Abandoned call records will be generated whether or
not incoming SMDR has been set.
Select whether to charge a transferred call to the source or
destination party.
This command assigns SMDR parameters for OLGs.
Specify the OLG for which to set SMDR parameters.
Enable SMDR Record Display.
Enable to generate records for outgoing calls. SMDR Record Display
must be on.
Enable to apply the SMDR record of a transferred call to its source or
its destination.
This assignment is used to view functions of the four control relays on
each BIOU PCB set in Program 105 12 Night Relay and 18 Night Bell
Relay; Program 508 Door Lock Control Assignment; and Program
503 19 BGM Mute Relay. The system allows up to two BIOU PCBs to
provide a total of eight control relays. The control relays can be
configured as an external BGM mute control, Night Bell control, Night
Mode Control, and Door Lock Control.
Notes
BIOU-1 relays are identified as Control Relays 1~4.
BIOU-2 relays are identified as Control Relays 5~8.
Enter the BOIU PCB number.
Note
BIOU 1 and BIOU 2 are assigned in Program 100 - Card
Assignment.
View the function of BIOU1, control relay 1 or BIOU2, control relay 5:
View the function of BIOU1, control relay 2 or BIOU2, control relay 6:
View the function of BIOU1, control relay 3 or BIOU2, control relay 7:
View the function of BIOU1, control relay 4 or BIOU2, control relay 8:
NOT USE ñ if the relay is not used.
PAGE MUTE ñ External BGM mute control activates during an
external page (see
ìProgram 503î on page
NIGHT BELL ñ Night Bell control activates during the system
Night Mode only when incoming CO lines ring (see
102î on page
12).
NIGHT RELAY ñ Night Mode Control activates continuously
during the system Night Mode (see
DOOR LOCK ñ Door Lock Control activates when a telephone's
Door Unlock button is pressed (see
Strata CIX/CTX Telephone Button Programming 11/04
75).
ìProgram
ìProgram 105î on page
18).
ìProgram 508î on page
78).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctxStrata ctx28Strata ctx100Strata ctx670

Table of Contents