Table 1-39
Programs 801~803
Button
Sequence
801
Network Jack LAN
Device Assignments
801
Hold
,
801-00
LAN Port Number
Hold
n,
801-01
Protocol
FB01
Hold
, n,
801-02
PC Operation Type
FB02
Hold
, n,
801-03
Data Flow
FB03
Hold
, n,
801-04
Server Port Number
FB04
Hold
, n,
801-05
Client IP Address
FB05, FB06, FB07,
801-06
or FB08
Hold
, n,
801-07
801-08
801-09
Write Retry Number
FB09
Hold
, n,
801-10
Write Retry Number
FB10
Hold
, n,
801-11
Write Retry Number
FB11
Hold
, n,
803
IO Logical Device
Assignment
803
Hold
,
803-00
Logical Device
Number
Hold
n,
1-94
Value(s)
n =
1~12 (default = no value)
n =
1. TCP (default)
2. UDP
n =
1. Server (default)
2. Client
n =
1. Synchronization
2. Asynchronization
(default)
n =
0~65535 (default = 0)
n =
0~255 (default = 0)
n =
0~65535 (default = 0)
n =
0~10 (default = 1)
n =
0~10 (default = 1)
Hold
,
n =
100 = SMDR
300 or 301 = SMDI
200~208 = CTI LAN
Devices of PCs (default =
no value)
400 = BLF
500 = DSS
Summary
This screen assigns the LAN parameters for the PC applications
connected to the BECU Network Jack through a LAN or Hub.
Enter the port number of the LAN device to be assigned. Refer to
Program 803 SMDR SMDI CTI Port Assignments.
Notes
Program the local port number for LCD Control of Voice Mail
Use the same Device Port No. (11) for Network BLF.
Use 10 for Network CTX Proprietary Integration
Use 12 for Network DSS
Network BLF and DSS are available only with CTX Release 1.3 or
higher software and with CTX WinAdmin Release 1.3 or higher
software.
Select communication Protocol.
Note
Select UDP for Network DSS.
Enter the application PC type: Server or Client.
Enter the data flow protocol that should take place between the CTX
and PC. If the PC is a CTX, CTI application assign ìAsynchronizationî
to data flow.
Enter the Server Port Number and proceed to 07 Read Retry
Number . This field is required if Server was selected in 02 PC
Operation Type above. If not, leave this field blank and proceed to 05
Client IP Address .
Note
Use 6000 for Network BLF, 3000 for Network DSS, and 5000
for Network CTX Proprietary Integration.
Enter the Client LAN IP Address. This field is required if Client was
selected in 02 PC Operation Type above.
0~255 for each octet (default = 0)
Enter IP address of Stratagy iES32 or SES.
Enter the Client Port number. This field is required if Client was
selected in 02 PC Operation Type above.
Set the Read Retry counter to (1~10).
Set the Write Retry counter to (1~10).
This screen is used to assign:
1. SMDR and SMDI to logical device and BSIS, RS-232 port
numbers.
2. CTX WinAdmin, ACD sever, and Attendant Console to BECU,
Network Jack logical device and LAN port numbers.
Enter the 3-digit logical device number for SMDR, SMDI, and LAN
device or PC application. See
SMDR: 100
SMDI: 300 or 301
CTI LAN devices or PCs can be assigned to any of the 9 LAN devices
numbers available: 200~208.
Strata CIX/CTX Telephone Button Programming 11/04
ìDevice Tableî
on
page 1-95

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctxStrata ctx28Strata ctx100Strata ctx670

Table of Contents