300 Series Programs
Table 1-31
Programs 318~320 (continued)
Button
Sequence
319
Intercept Treatment
319
Hold
,
319-00
Tenant Number
01
Day1 Destination
02
Day2 Destination
03
Night Destination
FB01
FB03
~
, n,
Hold
Hold
n1,
,
320
B Channel
320
Hold
,
320-00
RPTU Equipment No.
Hold
xxyyzz,
320-
B Channel
01~23
FB01
FB23
~
, n,
Hold
Table 1-32
B Channel Defaults
B Channel Position
Span Interface Speed
1.5M (T1)
2.0M (E1)
Table 1-33
Programs 321~324
Button
Sequence
321
Calling Number
Identification
321
Hold
,
321-00
OLG Number
Hold
n,
321-01
Default Number
FB01
Hold
, n,
1-70
Value(s)
n =
Enter 1~8
n =
1. None (default)
2. Dialing Digits
3. Night Bell
n1 =
Up to 32 digits
Spkr
,
xx =
xx = cabinet 01
yy =
yy = 03, 05, or 07
zz =
zz = Channel 01 is always
used to assign RPTU
parameters
or
xx = cabinet 02~10
yy = 01, 03, or 05
zz = Channel 01 is always
used to assign RPTU
parameters
n =
1. Enable (default)
2. Disable
Hold
,
01~15
ON
ON
Value(s)
n =
1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
n =
Up to 10 digits
This command assigns Intercept positions for Strata CTX Day/Night
schedules. Intercept positions are used when the destination of a
trunk line call is not determined with DID or DIT
Select the Tenant number for which the Intercept Destinations will be
configured.
Select Destination Type for each.
Enter Destination for each.
To intercept with a DN use 0~99999
To intercept with a Network DN use 1~32
To intercept with Dial Digits Paging 1~16
PRI interfaces are purchased on per interface and channel basis. The
ë Bí channel assignments allow for a flexible activation of channels to
match the subscribed services from the Public Service Telephone
Network.This command allows you to enable or disable each B
channel on selected RPTU PCBs.
Enter the ISDN RPTU equipment number.
Equipment numbers are required when assigning ISDN RPTU
parameters in the system. It can also be used to display the
equipment location of existing RPTU PCBs.
Example: If the RPTU is installed in cabinet shelf 5, slot 3, enter
050301.
Assign each ë Bí channel as enabled or disabled for each channel on
the interface. The assignments must match exactly to the subscription
from the PSTN.
16
17~23
ON
ON
OFF (Dch Pos)
ON
The Calling Number ID is what is defined as the user supplied Calling
Number. This number may be optionally screened by the PSTN to
ensure only calls from valid billable telephone numbers are allowed to
originate calls.
Enter the OLG Number.
Enter the telephone number to use by default when originating a call.
This is the number that the PSTN has registered for billing purposes.
Strata CIX/CTX Telephone Button Programming 11/04
Summary
24
25~31
OFF (Dch Pos)
ON
ON