System Type; Tx Freq Error - HP 8921A User Manual

Cell site test set
Hide thumbs Also See for 8921A:
Table of Contents

Advertisement

Chapter 6, Call Processing Subsystem
The CALL CONTROL Screen

System Type

NOTE:
If the Test Set is in the connected state (Connect annunciator is lit) and a change is made to
the System Type field, the connected state will be lost.

TX Freq Error

TX Power
128
This field is used to select the type of cellular system (AMPS, TACS, JTACS)
which will be simulated.
The
field is an immediate action field. That is, whenever the
System Type
field is changed, the change is reflected immediately in the
System Type
physical configuration of the Test Set. The control channel is immediately de-
activated, reconfigured, and then re-activated to reflect the change. This change
causes the Test Set to enter the active state).
This field displays the frequency error (frequency error = assigned carrier
frequency - measured carrier frequency) of the RF carrier being transmitted by the
mobile station. Four dashes (----) indicate that no RF carrier is present to measure.
A numeric value would only be displayed in the connected state (that is, the
annunciator is lit). The
Connect
the
field is set to
Display
The
field is displayed only when the
TX Power
This field displays the measured RF power of the RF carrier being transmitted by
the mobile station. A non-zero value would only be displayed when the Test Set's
annunciator is lit).
Connect
When the CALL CONTROL screen is displayed and the Test Set is in the
connected state (
Connect
carrier power is constantly monitored. If the power falls below 0.0005 Watts, the
error message
RF Power Loss indicates loss of Voice Channel
be displayed, and the Test Set will terminate the call and return to the active state
(
annunciator is lit).
Active
In order to ensure that the Test Set makes the correct decisions regarding the presence
of the mobile stations's RF carrier, the Test Set's RF power meter should be zeroed
before using the Call Processing Subsystem. Failure to zero the power meter can result
in erroneous RF power measurements. See
Processing" on page 130
TX Freq Error
.
Meas
Display
annunciator is lit), the mobile station's transmitted
"Conditioning the Test Set for Call
for information on manually zeroing the RF Power meter.
field is displayed only when
field is set to
Meas
.
will

Advertisement