Repeater System Effective Sensitivity Measurement - HP 8920A Application Handbook

Rf communications test set
Hide thumbs Also See for 8920A:
Table of Contents

Advertisement

Using the Tracking Generator

Repeater System Effective Sensitivity Measurement

Description
This procedure is used to measure the effective sensitivity of a repeater system
using the Spectrum Analyzer/Tracking Generator option. Once effective
sensitivity measured, receiver sensitivity degradation is calculated.
DUPLEX TEST
RF IN/OUT
POWER
OFF
ON
MAX POWER 60 W
!
CONTINUOUS
ANTENNA
(RF OUTPUT)
50Ω COXIAL
CABLE
228
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Knob
3
SCREEN CONTROL
MSSG
HELP
CONFIG
RX
TX
DUPLEX
USER
DATA FUNCTIONS
k1'
REF SET
INCR
k1
: 10
k2'
LO LIMIT
k2
k3'
CURSOR CONTROL
k3
ASSIGN
k4
RELEASE
PUSH TO SELECT
k5
SHIFT
CANCEL
MIC/ACC
VOLUME
DUPLEX OUT
ANT IN
!
M AX POWER 200 mW
TEST LOAD
1
REPEATER
Transmitter
Receiver
Receiver
Transmitter
Duplexer
Duplexer
Data Entry
Keys
INSTRUMENT STATE
HOLD
PRINT
ADRS
SAVE
MEAS
PREV
TESTS
LOCAL
RECALL
PRESET
RESET
DATA
METER
AVG
INCR
INCR X10
7
8
9
ENTER
SET
HI LIM IT
dB
GHz
4
5
6
dBm
%
MHz
1
2
3
V
s
+ _
kHz
0
mV
YES
NO
ms
ppm
%
Hz
ON/OFF
µV
W
dBµV
ME MORY
CARD
SQUELCH
AUDIO OUT
AUDIO IN
HI
LO
MAX
MAX
!
!
12 v Pk
42 v Pk
SPEAKER
+
(AUDIO
INPUT)
GND
ANTENNA
(RF INPUT)
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8920b

Table of Contents