TABLE VI - OPTIONS
Local keypad/
display
Local Auto/
manual switch
Handwheel
Certificates
Approvals
Shipped Rotation
TABLE VII - COMMUNICATIONS/PROTOCOL
None
Modbus RTU RS485
HART 5
TABLE VIII - MANUALS
Standard
TABLE IX - FACTORY OPTIONS
Factory Options
Restrictions
Restriction
Letter
a
b
c
ACCESSORIES
Mounting Hardware
Linkage Assembly
HART
Handheld Config.
(Note 3)
Remote Mount
Control
1. 135 ohm available by parallelling 1K potentiometer with 158 Ohm resistor (supplied).
Notes:
2. HercuLink
3. Requires PDA manufacturer's serial interface cable.
4. CSA approval is good for 75°C and a maximum relay load of 3.5 amps or 70°C with a
Revision 7
HercuLine™ 2000 Series Actuator - Installation, Operation and Maintenance Manual
7/08
No local display interface supplied
Integrally mounted local display/keypad interface
No auto/manual switch
Auto/manual switch with "Out of Auto Contact"
Auto/manual switch with "Out of Auto Contact"
No Handwheel
Handwheel
None
Certificate of Conformance
UL Type 4/IP66, CSA
CE
Counter clockwise shaft rotation on increasing signal
Clockwise shaft rotation on increasing signal
No communications option board or protocol
RS-485 Modbus compliant - standard with EEU
HART Communications Protocol
English
None
Available Only With
Table
Selection
IV
_ 00
II
150
090
II
Mounting plate adapter for Barber Colman Series MP495
Mounting plate adapter for Landis & Staefa SQM53/56
Direct Couple Valve Hardware
North American Valve Retrofit Kit
Ball joint for 5/16" dia. Pushrod
Pushrod 12 in. (304,5 mm) long, 5/16 " dia.
Pushrod 18 in. (457,2 mm) long, 5/16 " dia.
Pushrod 24 in. 609,6 mm) long, 5/16 " dia.
Pushrod 48 in. (1219,2 mm) long, 5/16 " dia.
Turk Cable for Handheld Connection
TM
HercuLink
Palm Software
Battery powered 232/485 converter with cable
Remote 4-20 mA requires 135 ohm fdbk, 120V 50/60Hz
Remote 4-20 mA requires 1000 ohm fdbk, 120V 50/60Hz
Remote 4-20 mA requires 135 ohm fdbk, 220V 50/60Hz
Remote 135 ohm input requires 135 ohm fdbk, 120V 50/60Hz
TM
software (pn 51452354-509), RS232/485 converter (pn 51452354-510),
TM
customer supplied Palm
PDA running OS3.5 or higher and Palm serial cable are required
for the 2001 and 2002 actuators if no display is selected.
relay load of 5 amps.
Selection
0_ _ _ _ _
(Note 2)
1_ _ _ _ _
_ 0_ _ _ _
_ 1_ _ _ _
_ 2_ _ _ _
_ _ 0_ _ _
_ _ 1_ _ _
_ _ _ 0 _ _
_ _ _ 1_ _
_ _ _ _ 0_
(Note 4)
_ _ _ _ 1_
_ _ _ _ _0
_ _ _ _ _1
Not Available With
Table
Selection
IV
_ 60, _ 80
II
090
150
II
Specifications
Model Selection Guide
2000 2001
2002 2003
0
1
2
0
00
51452354-501
51452354-502
51452354-503
51452354-511
51452354-504
51452354-505
51452354-506
51452354-507
51452354-508
51452352-501
51452354-509
51452354-510
R7195A1031
R7195A1056
R7195A1064
R7195B1021
11