Qlogic SANbox 9000 Series Interface Manual page 255

Stackable chassis switch
Hide thumbs Also See for SANbox 9000 Series:
Table of Contents

Advertisement

A
display [filter]
Specifies the log events to automatically display on the screen according to the
event severity levels given by [filter]. [filter] can be one of the following values:
Critical
Critical severity level events. The critical level describes events that are
generally disruptive to the administration or operation of the fabric, but
require no action.
Warn
Warning severity level events. The warning level describes events that are
generally not disruptive to the administration or operation of the fabric, but
are more important than the informative level events.
Info
Informative severity level events. The informative level describes routine
events associated with a normal fabric.
None
Specifies no severity levels for display on the screen.
level [filter]
Specifies the severity level given by [filter] to use in monitoring and logging events
for the specified components or ports. [filter] can be one of the following values:
Critical
Monitors critical events. The critical level describes events that are generally
disruptive to the administration or operation of the fabric, but require no
action. This is the default severity level.
Warn
Monitors warning and critical events. The warning level describes events
that are generally not disruptive to the administration or operation of the
fabric, but are more important than the informative level events.
Info
Monitors informative, warning, and critical events. The informative level
describes routine events associated with a normal fabric.
NOTE:
59231-03 A
Logging events at the Info severity level can deplete switch resources
because of the high volume of events.
15 – Command Reference
Set Log
15-89

Advertisement

Table of Contents
loading

Table of Contents