3.10.4 Network: Alarm Server

The ERS-4 can send network alarm notification to PowerCon software and other central management
systems, which support this function.
The notification can be transmitted to max. 3 receiving servers.
Server IP 1...3
Protocol Type
Port
Network ID
Apply
Enter the IP - addresses of the receiving alarm servers
Select the protocol type:
UDP: User Datagram Protocol
TCP: Transmission Control Protocol
Note: Use UDP only for LAN applications, this mode is not safe for Internet
connections.
User name of the dyndns.org account
Enter the network ID (Unique ID) for network alarm.
Note: 1. The ID must contain 10 numbers.
2. Only numbers are valid characters
3. Do not use leading zeros.
Click on
to finish and save the settings.