Running AutoCal™

AutoCal™ can be run at the end of either Cabling Wizards or from the GLM.SE™ Main Page menu "Setup
| GLM.SE™ Acoustic Wizard".
When the Sound Card Option window appears, select "AutoCal™ with Genelec sound card" and press
"Yes".
The AutoCal™ process consists of two main stages; firstly the acoustic responses of the SE7261A and
8130As are measured, secondly they are then aligned for flat response, equal delay and level. Below is a
more detailed description of what happens and needs to be done by the user:
Connect all the cables as described above.
Type and enter the serial number printed on the side of the Genelec 8200A Calibration
Microphone into the "Microphone Serial Number" box. This retrieves the calibration file for that
microphone. The calibration file corrects for small frequency response and sensitivity differences
between microphones.
Before starting the measurements, decide whether only the primary listening position is to be
measured (SinglePoint measurement) or whether additional measurement positions (MultiPoint
measurement) will be used.