Safety Label; Copy Of Safety Decal - HAMPTON BAY Hamilton H15 Owners & Installation Manual

Direct vent gas fireplace
Hide thumbs Also See for Hamilton H15:
Table of Contents

Advertisement

This is a copy of the label that accompanies
each Direct Vent Freestanding Gas Stove.
We have printed a copy of the contents here
for your review.
Listed:
VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour:
Tested to:
CGA-2-17-M91, ANSI Z21.88a-2007 / CSA 2.33a-2007
WN# 16443
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
NATURAL GAS STOVE:
L
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifice size
Altitude
PROPANE GAS STOVE:
Minimum supply pressure
L
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifice size
Altitude
Maximum Input
Minimum Input
Orifice size
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation
Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations
Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not
prohibited by local codes. See owner's manual for details.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1
en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured
Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations
Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U.
seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec
d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION -
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back
up in the same room where the gas appliance is installed.
Hampton® H15-1 Direct Vent Freestanding Gas Stove
é
CANADA and U.S.A.
APPAREIL FONCTIONNANT AU NATURAL GAS
Model H15-NG1
CONCU POUR ETRE POELE:
5"
WC/C.E. (1.25 kPa)
Pression d'allimentation minimum
3.8" WC/C.E. (0.94 kPa)
Pression
à
1.1" WC/C.E. (0.27 kPa)
Pression
à
18,000 Btu/h (5.28 Kw/h)
D bit Calorifique maximum
é
10,500 Btu/h (3.08 Kw/h)
D bit Calorifique minimum
é
#47 DMS
Dimensions de l'orifice
0-4500 ft/pi (0-1372m)
L'altitude
APPAREIL FONCTIONNANT AU PROPANE
Model H15-LP1
CONCU POUR ETRE POELE:
12"
WC/C.E. (3.00 kPa)
Pression d'allimentation minimum
11" WC/C.E.
(2.74 kPa)
Pression
à
la tubulure d' chappement lev e
2.9" WC/C.E.
(0.72 kPa)
Pression
à
la tubulure d' chappement basse
18,000 Btu/h
(5.28 Kw/h)
D bit Calorifique maximum
é
10,600 Btu/h
(3.10 Kw/h)
D bit Calorifique minimum
é
#55 DMS
Dimensions de l'orifice
0-2000 ft/pi
(0-610m)
L'altitude
15,500 Btu/h
(4.54 Kw/h)
D bit Calorifique maximum
é
8,200 Btu/h
(2.40 Kw/h)
D bit Calorifique minimum
é
#56 DMS
Dimensions de l'orifice
2000-4500 ft/pi (610-1372m)
L'altitude
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil.
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
DUPLICATE SERIAL NO.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
Modéle H15-NG1
la tubulure d' chappement lev e
é
é
é
la tubulure d' chappement basse
é
Modéle H15-LP1
é
é
é
é

SAFETY LABEL

NOTE: Hampton
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
301
Serial No./ No de serie
301
Minimum Clearances to Combustibles /
Degagement Minimum
De Materiaux Combustibles
Left Side Wall
Left Side Wall
A
A
C
B
Vertical
Horizontal
Pipe
Pipe
A
A
36" max
36" max
Right Side Wall
Right Side Wall
E
E
Minimum ceiling height from top of unit:
24"/610
mm
Minimum plafond hauteur en haut de
l'appareil: 24"/610mm
C 2" / 50mm
A 6" / 150mm
E 2" / 50mm
B 0" / 0mm
See Manual for details
Minimum clearance of Vent Terminal
to Outside Corner & Inside Corner:
with AstroCap 6"/150mm
with Dura-Vent Cap 12"/300mm
Electrical supply / Élec trique 115VAC, 1.13 A, 60Hz.
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Made in Canada/
Fabrique au Canada
918-494b
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H15-ng1H15-lp1

Table of Contents