INSTALLATION
o
One 90
elbow = Two 45
Option V
H
A)
1' Min.
4' Max. 2' Min.
B)
2' Min.
5' Max. 3' Min.
C)
3' Min.
6' Max. 4' Min.
D)
4' Min.
7' Max. 5' Min.
E)
5' Min.
8' Max. 6' Min.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the "Vent
Restrictor Postion" section.
Option
H + H1
o
One 90
elbow = Two 45
A)
2' Max.
2' Min.
B)
3' Max.
3' Min.
C)
4' Max.
4' Min.
D)
5' Max.
5' Min.
E)
6' Max.
6' Min.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the
"Vent Restrictor Postion" section.
18
Vertical Venting with Two (2) 90
o
elbows.
V + V1
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is re-
quired.
Vertical Venting with Two (2) 90
V
o
elbows.
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
6 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
o
Elbows
V1
o
Elbows
V
H1
V
H
H
Hampton® H15-1 Direct Vent Freestanding Gas Stove