Dura-Vent Termination Kit - HAMPTON BAY Hamilton H15 Owners & Installation Manual

Direct vent gas fireplace
Hide thumbs Also See for Hamilton H15:
Table of Contents

Advertisement

INSTALLATION
Installation
There are two basic types of Dura-Vent Direct
Vent System installations: horizontal termination
and vertical termination. Confi rm the maximum
horizontal run and maximum vertical rise from
the diagrams in the "Rigid Pipe Venting Sys-
tems" section.
When planning your installation, it will be nec-
essary to select the proper length of vent pipe
for your particular requirements. For horizontal
installations, determine the minimum clearance
from the rear of the unit to the wall. It is also
important to note the wall thickness. (The wall
thimble is suitable for 2 x 4 or 2 x 6 wall construc-
24

DURA-VENT TERMINATION KIT

Planning Your Dura-Vent
tion.) Select the amount of vertical rise desired
for "vertical-to-horizontal" type installations.
Warning: Always maintain required
clearances (air spaces) to nearby
combustibles to prevent a fire
hazard. Do not fi ll air spaces with
insulation.
The minimum clearance requirements between
the outer wall of the vent pipe and nearby com-
bustible surfaces is 1-1/4 inch. Be sure to check
the vent termination clearance requirements
from decks, windows, soffi ts, gas regulators, air
supply inlets and public walkways as specifi ed
1
1 Wall Thimble Cover
1 Horiz. Sq. Term. Cap
in the "Exterior Vent Terminal Locations" section
and in your local building codes.
To determine the length of vent pipe required
for vertical installations, measure the distance
from the unit fl ue outlet to the ceiling, the ceiling
thickness, the vertical rise in an attic or second
storey, and allow for suffi cient vertical height
above the roof line.
For multi-storey applications, fi re stops are
required at each fl oor level. If an offset is
needed, additional pipe, elbows and supports
will be required.
Do not exceed the maximum number of elbows.
o
One 90
for horizontal terminations and two 45
for vertical termination.
You will require the following components with
your new Direct Vent Freestanding Gas Stove.
Alternate Horizontal
Part# 946-523/P
Basic
Horizontal Kit
90
o
Elbow
TM
The FPI AstroCap
is certifi ed for installations using FPI venting
systems as well as Simpson Dura-Vent® and Direct Vent.
The FPI AstroCap
TM
is a proprietary trademark of FPI Fireplace Prod-
ucts International Ltd.
Dura-Vent® and Direct Vent are registered and/or proprietary trade-
marks of Simpson Dura-Vent Co. Inc.
Hampton® H15-1 Direct Vent Freestanding Gas Stove
Termination Caps
AstroCap
Alternate
Horizontal
Riser Vent
Terminal
Part# 640-530/P
o