Copy Of Safety Label - HAMPTON BAY H27-NG10 Owners & Installation Manual

H27 series
Table of Contents

Advertisement

safety decal
|
4
This is a copy of the label that accompanies
each Direct Vent Freestanding Gas Stove.
We have printed a copy of the contents here
for your review.

COPY OF SAFETY LABEL

Listed: VENTED GAS FIREPLACE HEATER /
FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour: CANADA and U.S.A.
Tested to:
Conforms to:
Certified to:
4001172
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
FACTORY EQUIPPED FOR NATURAL GAS
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifice size
Altitude
FACTORY EQUIPPED FOR PROPANE GAS
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifice size
Altitude
Minimum Clearances to Combustibles/Degagement Minimum De Materiaux Combustibles
Minimum ceiling height from top of unit:24"/610mm
Minimum plafond hauteur en haut de
l'appareil: 24"/610mm
C 2" / 50mm
A 6"/150mm
E 2"/50mm
B 3"/75mm
Minimum clearance of Vent Terminal
to Outside Corner & Inside Corner:
with AstroCap 6"/150mm
with Dura-Vent Cap 12"/300mm
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or
Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable,
ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. Optional Fan Kit (Part # 357-917)
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1,
National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24
CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme
ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
For Use Only with Barrier (Part # 743-100) Follow installation instructions.
Utiliser uniquement avec l'écran ( n ° 743-100) Suivre les instructions d'installation.
ELECTRICAL SUPPLY/ALIMENTATION ELECTRIQUE:115V_60HZ less than/moins de 2 AMP
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION -
FPI Fireplace Products International Ltd. Delta, BC, Canada
Made in Canada/Fabrique au Canada
For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the
Commonwealth of Massachusetts.
Part #: 919-485a
Colour: Everything black on grey except for items indicated as being printed in red.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
Size:
Printed at 100%
Material: 2 ml silver matt polyester (DPM SMS)
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
Dec. 09/14: Created decal
Apr. 9/15: Rev. A - updated data
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720
and a CO alarm with battery back up in the same room where the gas appliance is installed.
*Printer: Continue number sequence from 918-813 - do not restart at 0
4
|
Hampton
H27-10 Direct Vent Freestanding Gas Stove
®
NOTE: Hampton
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
é
CAN/CGA-2.17-M91(R2009)
ANSI Z21.88-2014
CSA 2.33-2014
Model:H27-NG10
5"
WC/C.E. (1.25 kPa)
3.5" WC/C.E. (0.87 kPa)
1.6" WC/C.E. (0.40 kPa)
25,000 Btu/h (7.32 Kw/h)
18,000 Btu/h (5.28 Kw/h)
#42 DMS
(2.37mm)
0-4500 ft/pi (0-1372m)
Model:H27-LP10
11" WC/C.E.
(2.74 kPa)
10" WC/C.E.
(2.49 kPa)
6.4" WC/C.E. (1.59 kPa)
22,000 Btu/h (6.45 Kw/h)
17,500 Btu/h (5.13 Kw/h)
#54 DMS
(1.4mm)
0-4500 ft/pi (0-1372m)
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
units are constantly being
®
DUPLICATE SERIAL NO.
NE PAS ENLEVER CETTE ÉTIQUETTE
É
QUIP
É
A L'UISINE POUR GAZ NATURAL
Pression d'allimentation minimum
Pression
la tubulure d' chappement lev e
à
Pression
la tubulure d' chappement basse
à
D bit Calorifique maximum
é
D bit Calorifique minimum
é
Dimensions de l'orifice
L'altitude
É
QUIP
É
A L'UISINE POUR GAZ PROPANE
Pression d'allimentation minimum
Pression
la tubulure d' chappement lev e
à
Pression
la tubulure d' chappement basse
à
D bit Calorifique maximum
é
D bit Calorifique minimum
é
Dimensions de l'orifice
L'altitude
Left Side Wall
Left Side Wall
Vertical
Horizontal
Pipe
Pipe
Right Side Wall
Right Side Wall
351
DO NOT REMOVE THIS LABEL /
351
Serial No./ No de serie
é
é
é
é
é
é
é
é
See Manual for details
919-485a

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H27-lp10