HAMPTON BAY HI300 Owners & Installation Manual
HAMPTON BAY HI300 Owners & Installation Manual

HAMPTON BAY HI300 Owners & Installation Manual

Wood cast insert

Advertisement

Wood Cast Insert
Owners &
Installation Manual
www.hampton-fire.com
MODEL:
HI300
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-240k
11/25/14

Advertisement

Table of Contents
loading

Summary of Contents for HAMPTON BAY HI300

  • Page 1 Wood Cast Insert Owners & Installation Manual www.hampton-fire.com MODEL: HI300 Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4...
  • Page 2 The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit. Hampton HI300 Wood Cast Insert...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Safety Guidelines ............23 Safety Label For Hi300 ..........4 First Fire ..............23 Creosote ..............24 Ash Disposal..............24 UNIT DIMENSIONS Fan Operation .............24 Wood Storage ..............24 Door Gasket ..............25 with standard ..............5 Glass Cleaning ............25 Cast faceplate..............5 Door Removal..............25...
  • Page 4: Safety Label

    NOTE: Hampton units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. Hampton HI300 Wood Cast Insert...
  • Page 5: With Standard

    DIMENSIONS WITH STANDARD CAST FACEPLATE NOTE: Before assembling your Insert, use these dimensions to ensure appropriate clearances will be met (refer to Masonry and Fac- tory Built Fireplace Clearances section). Hampton HI300 Wood Cast Insert...
  • Page 6: With Oversize

    DIMENSIONS WITH OVERSIZE NOTE: CAST FACEPLATE Before assembling your Insert, use these dimensions to ensure appro- priate clearances will be met (refer to Masonry and Factory Built Fireplace Clearances section). Hampton HI300 Wood Cast Insert...
  • Page 7: Installation

    Emissions from burning wood or gas could to install the chimney liner. contain chemicals known to the State of Cali- fornia to cause cancer, birth defects or other reproductive harm. Hampton HI300 Wood Cast Insert...
  • Page 8: Masonry And Factory Built Fireplace Clearances

    Compare proposed system R of 1.231 to R = 1/k x T = 1/0.84 x .75 = 0.893. specified R of 0.893. Since proposed system R is greater than required, the system is Thermal Resistance: acceptable. )(hr)( F) = )(K) Hampton HI300 Wood Cast Insert...
  • Page 9: Installing Your Insert

    Be sure to leave the unit out at least 3 to 4 inches in order to make the necessary flue connections and to install the faceplate. Be sure to protect your hearth extension during the installation, ie. with a heavy blanket. Hampton HI300 Wood Cast Insert...
  • Page 10: Installation Into Amasonry Fireplace

    When a connected flue or liner is in use, the insert is able to “breathe” better by allowing a greater draft to be created. The greater draft can decrease problems such as, difficult start-ups, smoking out the door, and dirty glass. Hampton HI300 Wood Cast Insert...
  • Page 11: Stainless Steel Smoke Deflector Adjustment / Replacement

    WARNING: Operation of the unit with out proper installation of smoke deflector will void warranty. Ensure defector is seated so bolts are situated at the top of the keyhole before tightening. Hand tighten bolts only. Hampton HI300 Wood Cast Insert...
  • Page 12: Standard Cast Faceplate Installation

    Mantel Top. If there is a gap present you will need to lower that side cast by loosening 2 bolts, see step 6 for bolt location (check to see if level). Hampton HI300 Wood Cast Insert...
  • Page 13 Carefully slide the Mantel Top back into position. Slide Mantel Top back. Cast Cast adjustment mounting bolts bolts for height adustment. See Step 3 to identify side casts. See next page for recommended measurements. 12/23/10 918-300g Page 2 of 3 Hampton HI300 Wood Cast Insert...
  • Page 14 Important: Verify gap between cast and door did not change when rear adjustments have been made. Carefully open door slowly, to ensure that the door does not rub against cast sides. These are just recommended measurements. 12/23/10 918-300g Page 3 of 3 Hampton HI300 Wood Cast Insert...
  • Page 15: Oversize Cast Faceplate Installation

    Mantel Top Spacer and the underside cast of the Mantel Top. If there is a gap present you will need to lower that side cast by loosening 2 bolts, see side cast adjustment section for bolt location (check to see if level). Hampton HI300 Wood Cast Insert 05/02/11 918-967...
  • Page 16 11) The unit may now carefully be slid into fi nal position. See side cast adjustments if faceplate needs aligning. Right Side Face- Left Side Faceplate plate Backside of Unit & Faceplate Shown. Hampton HI300 Wood Cast Insert 918-967 05/02/11...
  • Page 17 Important: Verify gap between cast and door did not change when rear adjustments have been made. Carefully open door slowly, to ensure that the door does not rub against cast sides. These are just recommended measurements. Hampton HI300 Wood Cast Insert 05/02/11 918-967...
  • Page 18: Cast Grill Installation

    5. Lift the bottom of the glass upwards till it stops, secure glass retainer using the 8 bolts. Do not wrench down on the bolts, as this may cause the glass to break. 04/19/12 919-151 Hampton HI300 Wood Cast Insert...
  • Page 19: Fan Installation

    Switch Plate. Neutral Green Manual/ Live Ground Auto 120V AC Switch Switch 60 Hz Fan Thermodisc (normally open) Black Black Black Ground Ashlip Blower/Fan Wiring Diagram Draft Control Support Clips Switch Plate Hampton HI300 Wood Cast Insert...
  • Page 20: Power Outlet Conversion

    8) Attach the green ground wire with the #8 x 3/8" Pan other side. Head Phillips steel self tapping screw, previously removed from the left side. Hampton HI300 Wood Cast Insert 918-378 07/23/08...
  • Page 21 12) Attach the fan defl ector to the main fan body by replacing the Phillips screw on the top of the fan housing. Thermodisc Assembly Template (If required) Location of New Thermdisc Holes Thermodisc As- sembly Base Location of Old Thermdisc Holes Diagram 1 918-378 07/23/08 Hampton HI300 Wood Cast Insert...
  • Page 22: Firebrick Assembly

    Install the air tube into the holes in the side channels. The notch goes on the right hand side with the air holes facing toward the door. Slide the tube into the left Front View Hampton HI300 Wood Cast Insert...
  • Page 23: Operating Instructions

    16) The controls of your unit should not be maximum setting, and only after the metal altered to increase firing for any reason. has been warmed. How to Light & Maintain a Wood Stove Fire Hampton HI300 Wood Cast Insert...
  • Page 24: Creosote

    (3mm / 1/8" or more) it should be removed to reduce the risk of a chimney fire. Hampton HI300 Wood Cast Insert...
  • Page 25: Door Gasket

    After re-installing the door, carefully swing open and check the clearance to the Right Hand Cast Side. If tight or rubbing, loosen the 7/16 nuts and adjust the clearance and then re-tighten. Cleaning & Maintaining Your Wood Stove Hampton HI300 Wood Cast Insert...
  • Page 26: Latch Adjustment

    4) Re-secure Latch to Mounting Bracket using 2 bolts. Latch Assembly re-assembled with spacers removed. Mounting Latch Bracket 5) Re-secure the Latch Assembly to the unit using 2 bolts. Cleaning & Maintaining Your Wood Stove Hampton HI300 Wood Cast Insert...
  • Page 27 Check glass for cracks Replace if required. Clean blower motor Disconnect power supply. Remove and clean blower. *DO NOT LUBRICATE* Inspect and clean chimney Annual professional chimney cleaning recommended. Cleaning & Maintaining Your Wood Stove Hampton HI300 Wood Cast Insert...
  • Page 28: Main Assembly

    942-671* Left Side Cast * Last digit of part number represents color: 936-238 Side Cast Gasket 1 = Metallic Black, 5 = Timberline Brown, 23) 940-370/P Door Glass 846-570 Door Gasket Kit Part # Description Hampton HI300 Wood Cast Insert...
  • Page 29: Standard Cast Faceplate

    Cast Faceplate - Metallic Black 300-925 Cast Faceplate - Timberline Brown 300-926 Cast Faceplate - Enamel Black 200) * Top Faceplate 201) * Left Side Faceplate 202) * Right Side Faceplate * Not available as a replacement part. Hampton HI300 Wood Cast Insert...
  • Page 30: Oversize Cast Faceplate

    Cast Faceplate - Timberline Brown 300) * Top Faceplate 301) * Left Side Faceplate 302) * Right Side Faceplate 303) 300-060 Mounting Plate LH 300-061 Mounting Plate RH 304) 300-005 Top Retainer * Not available as a replacement part. Hampton HI300 Wood Cast Insert...
  • Page 31: Brick Panels

    PARTS LIST BRICK PANELS Part # Description 180-960 Brick Set - Complete Hampton HI300 Wood Cast Insert...
  • Page 32 NOTES Hampton HI300 Wood Cast Insert...
  • Page 33 NOTES Hampton HI300 Wood Cast Insert...
  • Page 34 NOTES Hampton HI300 Wood Cast Insert...
  • Page 35: Warranty

    HI300: Steel fi reboxes to be free from defects in materials and workmanship, also covered are vermiculite baffl es and air tubes (against warpage) against manufacturer's defects for a period of 3 years parts and subsidized labor and parts only thereafter.
  • Page 36 Register your Regency warranty online ® www.regency-fire.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

Table of Contents