H15 Direct Vent Gas Fireplace
MODELS:
H15E-NG11 Natural Gas
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Testedby:
Certifiedto/Certifiépour:CSA2.17-2017
ANSIZ21.88-2017
CSA2.33-2017
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
919-880e
H15E-LP11 Propane
Installer:   P leasecompletethedetailsonthebackcover
andleavethismanualwiththehomeowner.
Homeowner: Pleasekeeptheseinstructionsforfuturereference.
Owners &
Installation Manual
www.hampton-fire.com
01.12.21

Advertisement

Table of Contents
loading

Summary of Contents for HAMPTON BAY H15E-NG11

  • Page 1 Owners & H15 Direct Vent Gas Fireplace Installation Manual www.hampton-fire.com MODELS: H15E-NG11 Natural Gas H15E-LP11 Propane WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: OnDemandPilotLight(SevenDaySafetyTimer)

    HAMPTON ® Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! Youaretheownerofastate-of-the-artHampton GasStovebyFPIFIREPLACEPRODUCTSINTERNATIONALLTD. ® TheH15E-11isahandcraftedapplianceandhasbeendesignedtoprovideyouwithallthewarmthandcharmofawood fireplaceattheflickofaswitch.ThemodelH15E-11hasbeenapprovedbyWarnockHersey/Intertekforbothsafetyand efficiency.Asitalsobearsourownmark,itpromisestoprovideyouwitheconomy,comfortandsecurityformanytrouble freeyearstofollow.Pleasetakeamomentnowtoacquaintyourselfwiththeseinstructionsandthemanyfeaturesofyour Hampton Stove. ® ON DEMAND PILOT LIGHT (SEVEN DAY SAFETY TIMER) Important information if using the appliance in CPI (continuous pilot mode) only ThisapplianceisaProFlame2systemfittedwiththe“OnDemand”Pilot,asafetyfeaturewhichwillshutdownthegasvalvecompletely byextinguishingthepilotlightintheeventofacontinuousfullsevendaysofinactivity.
  • Page 3: Table Of Contents

    dimensions owner's information OnDemandPilotLight(sevendaysafetytimer)...2 Dura-VentTerminationKit ..........31 UnitDimensionswithhorizontalvent ......4 Horizontalterminations ..........32 UnitDimensionswithverticalvent .........5 VerticalTerminations...........33 ImportantMessage ............8 ConvertingClass-AMetalChimneyto Specifications..............8 DirectVentSystem............35 Mobile/ManufacturedHomesAfterFirstSale....8 CathedralCeilings............36 BeforeYouStart .............8 HighElevation ..............36 LightingProcedure............9 GasConnection ............36 CopyoftheLightingPlateInstructions.......10 AerationAdjustment............37 ProflameIIremotecontroloperatingInstructions ..11 GasPipePressureTesting..........37 885S.I.T.ValveDescription.........37 installer's information...
  • Page 4: UnitDimensionsWithHorizontalVent

    dimensions UNIT DIMENSIONS WITH HORIZONTAL VENT 20-11/16" (525mm) 19-1/8" (485mm) 14-1/4 (361mm) 19-3/8" 13-5/8" (492mm) (345mm) ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. Hampton®H15E-11DirectVentFreestandingGasStove...
  • Page 5: UnitDimensionsWithVerticalVent

    dimensions UNIT DIMENSIONS WITH VERTICAL VENT Hampton®H15E-11DirectVentFreestandingGasStove...
  • Page 6 Refer to Intertek's Directory of Building Products for detailed information. C #: 4001172 Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek. NATURAL GAS STOVE: Model H15E-NG11 APPAREIL FONCTIONNANT AU GAZ NATUREL Minimum Clearances to Combustibles / Modèle H15E-NG11 Dégagements minimaux...
  • Page 7 requirements installer's information MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 8: ImportantMessage

    SPECIFICATIONS AND OTHERS MAY BE SUSCEPTIBLE is used. TO ACCIDENTAL CONTACT BURNS. A Fuels: H15E-NG11 is approved for use with PHYSICAL BARRIERS IS RECOMMEND- naturalgas. ED IF THERE ARE AT RISK INDIVIDUAL BEFORE YOU START IN THE HOUSE. TO RESTRICT ACCESS...
  • Page 9: LightingProcedure

    owner's information LIGHTING PROCEDURE Note:Thefirsttryforignitionwilllastapproximately60seconds.Ifthereisno IMPORTANT: The remote control system supplied with this appliance has severaloptionsforstarting/operatingtheapplianceusingthepowerbutton flameignition(rectification)theboardwillstopsparkingforapproximately  andON/OFFkeyonthehandheldtransmitter. 35seconds.Afterwaittime,theboardwillstartsecondtryforignitionby Priortooperatingthisappliance,pleasereadtheremotecontroloperating sparkingforapproximately60seconds.Ifthereisstillnopositiveignition instructions(packagedwithremotecontrol)tounderstandhowtooperate theboardwillgointolockout. thisremotecontrolsystem. Thesystemwillneedtoberesetasfollows: 1.EnsuretheMainswitchisintheONposition. a)Wait5minutes-turnthesystemoffbypressingtheON/OFFbuttonon theremote. 2.PressandreleasetheON/OFFbuttonontheremotehandheldtransmitter b)Afterapproximately2secondsturnonON/OFFswitchorpressON/OFF (seeDiagram2).AnaudiblebeepshouldbeheardfromtheIFC. buttonifusingoptionalremote. c)Repeatstep2. SHUTDOWN PROCEDURE 1. PresstheON/OFFbuttonontheremote 2. Ifserviceistobeperformed-youmustdisconnectpowerandshutoffgas totheunit.
  • Page 10: CopyOfTheLightingPlateInstructions

    owner's information COPY OF THE LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING POUR VOTRE SÉCURITÉ – À LIRE AVANT LA MISE EN MARCHE This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1.
  • Page 11: ProflameIiRemoteControlOperatingInstructions

    owner's information PROFLAME II REMOTE CONTROL OPERATING INSTRUCTIONS PROFLAME II REMOTE CONTROL OPERATING INSTRUCTIONS IMPORTANT:The Proflame Transmitter 2 is an integrated part of the TECHNICAL DATA Proflame 2 System, which consists of these elements: • Proflame 2 Transmitter, to be used in conjunction with: REMOTE CONTROL •...
  • Page 12 owner's information Temperature indication Display Remote‑Flame Control With the system in the "OFF" position, press the Thermostat Key and The Proflame has six (6) flame levels. With the system on, and the flame the Mode Key at the same time. Look at the LCD screen on the transmit- level at the maximum in the appliance, pressing the Down Arrow Key ter to verify that a C or F is visible to the right of the room temperature once will reduce the flame height by one step until the flame is turned off.
  • Page 13 owner's information Smart Thermostat (Transmitter Operation) Remote dimmer control (Light)** The auxiliary function controls the AUX power outlet by the dimmable The Smart Thermostat function adjusts the flame height in accordance light control. To activate this function use the Mode Key (fig. 1) to index to the difference between the set point temperature and the actual room to the AUX icon (fig.
  • Page 14 owner's information Continuous Pilot/Intermittent Pilot (CPI/IPI) selection 5. "Clr" will remove a mode—use the up or down arrow while holding down ON/OFF and MODE (mode icon will disappear once removed). Note: Power vent models do not have a Continuous 6. Use the "MODE" button to move to the next function. Pilot option.
  • Page 15: Installer's Information

    requirements installer's information 1) Provide adequate clearances for servicing, lint from carpeting, bedding material, etc. It 8) Installstandardandoptionalfeatures.Referto isimperativethatcontrolcompartments,and thefollowingsectionswhereapplicable: properoperationandaroundtheairopenings circulatingairpassagewaysoftheappliance intothecombustionchamber. bekeptcleanandfreefromexcessivelintfrom a.LogSetInstallation 2) Theappliancemustbeinstalledonaflat,solid, carpeting. b.WallThermostat c.RemoteControl continuoussurface(e.g.wood,metal,concrete). 4) See general construction and assembly in- Thismaybethefloor,oritcanberaisedup structions.Theapplianceandventshouldbe 9) Finalcheck.Refertothe"FinalCheck"section.
  • Page 16: ClearancesToCombustibles

    *12'max.onlyifverticalheightisachieved. installeddirectlyoncarpetingorvinyl. A) CrossCorner Use the minimum clearances shown in the dia- B) RoomDivider gramsbelow: C) Island D) FlatonWall H15E-NG11 & H15E-LP11Clearances E) FlatonWallCorner A LeftSideWalltoUnit* 6"/150mm F) FlushwithWall/Alcove *B B ackWalltoUnit 0"/0mm For V ent T erminationrequirements,seethe"Exterior 2. L oosenboltssecuringcastfront–slidelightas- C VerticalVentPipetoBackWall VentTerminalLocations"section.
  • Page 17: OptionalFanInstallation

    installation OPTIONAL FAN INSTALLATION OPTIONAL FAN INSTALLATION Tuck the fan assembly in behind the legs Remove left side access panel (when as shown. On either side of the unit there facing front) by removing one screw. will be slits located on the body of the Remove the rear access panel on the back of stove.
  • Page 18: GlassFront

    installation GLASS FRONT 4. Slidethelightassemblybracketoutoftheway. REMOVAL / INSTALLATION 1. T urnoffstoveandallowtoreturntoroomtem- perature. 2.Liftoffcasttopandplaceonasoftsurface. 5. Lift both latches securing glass door and re- movedoor. 3.Remove2boltsandliftoffcastfront-placefront carefullyonasoftsurface. 6. Toreinstall–reversesteps. Hampton®H15E-11DirectVentFreestandingGasStove...
  • Page 19: VentingIntroduction

    SAFETY PRECAUTIONS FOR THE INSTALLER The HorizontalTermination Kit and the Simpson Theseventingsystemsareengineeredproducts Dura-Vent Direct Vent venting systems, in com- thathavebeendesignedandtestedforusewith 1) Wearglovesandsafetyglassesforprotec- bination with the  Direct Vent Freestanding Gas theH15E-NG11,andH15E-LP11. T hewarrantywill tion. Stoves,H15E-NG11,andH15E-LP11,havebeen bevoidedandseriousfire,healthorothersafety testedandlistedasdirectventheatersystemsby hazardsmayresultfromanyofthefollowingactions: 2) Exerciseextremecautionwhenusinglad- WarnockHersey. dersoronrooftops.
  • Page 20: ExteriorVentTerminalLocations

    installation EXTERIOR VENT TERMINAL LOCATIONS Minimum Clearance Requirements Canada Clearanceabovegrade,veranda,porch,deck,orbalcony 12"(30cm) 12"(30cm) Clearancetowindowordoorthatmaybeopened 12"(30cm) 9"(23cm) Clearancetopermanentlyclosedwindow Verticalclearancetoventilatedsoffitlocatedabovetheterminalwithinahorizontaldistanceof2feet(61cm) 22"(56cm) 22"(56cm) fromthecenterlineoftheterminal(checkwiththelocalcode) Clearancetounventilatedsoffit 12"(30cm) 12"(30cm) Clearancetooutsidecorner:withAstroCapandVentRiserTerminationCap 6"(15cm) 6"(15cm) Clearancetooutsidecorner:withallotherapprovedTerminationCaps. 12"(30cm) 12"(30cm) Clearancetoinsidecorner:withAstroCap andVentRiserTerminationCap 6"(15cm) 6"(15cm) Clearancetoinsidecorner:withallotherapprovedTerminationCaps 12"(30cm) 12"(30cm) Clearancetoeachsideofcenterlineextendedabovemeter/regulatorassembly 36"(90cm) Clearancetoserviceregulatorventoutlet 36"(90cm) Clearancetonon-mechanicalairsupplyinlettobuildingorthecombustionairinlettoanyotherappliance 12"(30cm) 9"(23cm)
  • Page 21: 4"X6-5/8"RigidPipe

    installation 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART 4" X 6-5/8" RIGID PIPE CROSS REFERENCE CHART ComponentsfromdifferentManufacturersmaynotbemixed.NotAllRigidPipecomponentsareavailabledirectlyfromFPI. Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: OlympiaVentisDVventingisonlyapprovedforcertainmodels.Seelistofapprovedmodelsincross-referencechart. Note: Olympia Ventis DV venting is only approved for certain models. See list of approved models in cross-reference chart. Description *Selkirk *American Metal...
  • Page 22 installation Description *Selkirk *American Metal *Security *ICC Excel *Olympia Simpson *Metal-Fab™ Ventis DV*** Direct Temp™ Secure- Vent® Direct ® Products® Direct Vent Pro Sure Seal Amerivent Direct Attic Insulation Shield 12" 46DVA-IS 4DAIS12 4DIS SV4RSA VDV-AIS04 Attic Insulation Shield 46DVA-KHA 4DAIS12 TM-4AS - Cold Climates 36"...
  • Page 23: RigidPipeVentingSystems

    installation RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations Alternate Vertical Horizontal Termination Termination Caps Storm Collar Vinyl Siding Standoff (Optional) Flashing Horizontal Termination Ceiling Firestop Wall Thimble Pipe Length Adj.Pipe Length 11" - 14-5/8" 90 Elbow WARNING: Do not combine venting components from 24"...
  • Page 24 installation Horizontal Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option H + H1 With these options, maxi- A) 1'Min. 3'Max. mumtotalpipelengthis30 B) 2'Min. 4'Max. feetwithminimumof6feet totalverticalandmaximum C) 3'Min. 5'Max. 8feettotalhorizontal. D) 4'Min. 6'Max. Please note minimum 1 E) 5'Min. 7'Max.
  • Page 25 installation Vertical Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbow Option V + V1 With these options, maxi- mumtotalpipelengthis30 1'Min. 4'Max. 2'Min. feetwithminimumof6feet totalverticalandmaximum 2'Min. 5'Max. 3'Min. 8feettotalhorizontal. 3'Min. 6'Max. 4'Min. Please note minimum 1 foot between 90 elbows 4'Min.
  • Page 26: VentingArrangements

    installation VENTING ARRANGEMENTS Horizontal Terminations for Vertical Terminations Systems for Residential Manufactured and Mobile Homes All Venting Systems The shaded areas in the diagram below show all The shaded area in the diagram below shows all allowable combinations of straight allowable combinations of vertical runs with hori- vertical and offset to vertical runs with vertical terminations.Maximum two 45 elbows.
  • Page 27: VerticalTerminationWithCo-LinearFlexSystem

    installation VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE Masonrychimneysmaytakevariouscontourswhichtheflexiblelinerwillaccommodate.However,keep CONNECTED TO A CHIMNEY FLUE the flexible liner as straight as possible,avoidunnecessarybending. SERVING A SEPARATE SOLID FUEL TheAirIntakepipemustbeattachedtotheinletaircollaroftheterminationcap. BURNING APPLIANCE. This appliance is designed to be attached to Required Parts: two3"(76mm)co-linearaluminiumflexrunning thefulllengthofthechimney.SeetheVenting...
  • Page 28: DvStoveHorizontalVentKit

    installation DV STOVE HORIZONTAL VENT KIT DV2ft.StoveVentKit(Part#946-116)andDV4ft.StoveVentKit(946-216)includesallthepartsneededto installtheH15-10DirectVentunitwithup&outhorizontalandverticalventdimensions.Forinstallationsthat requirelongerverticaland/orhorizontalventsusetheDura-Ventsystemasshowninthe"Dura-VentTermina- tionKit"and"Dura-VentVentingComponents"sections. Qty. Description 1) 1  RigidPipeSection(Kit#946-116:2ft.(1.2m)length,  Kit#946-216:4ft.(1.2m)length),6-1/2"(165mm)  insidediameter 2) 1  FlexLiner,compressedaluminium2plyliner,4"(102mm)  insidediameter 3) 4  springspacers 4) 1  90deg.Elbow 5) 1  Adjustablepipesection13-1/2"to24"(343mmx610mm),2pcs. 6) 1  ThimbleCover 7) 1  WallThimble(2pcs.)
  • Page 29 installation 10)Slide the decorativeThimble Cover over the pipesectionsandsecurewith4screws(#8x 1-1/2"drillpoint,black)tothewall. 11)Slide the 90  elbow (crimp end up), the 45 elbowandthe4ft.pipesection(crimpendup) overthe4"dia.flexliner. 12)Installthespringspacersontothepipesections. 13)Securethe4"dia.flexlinerwithadapteronto thestovecollar.PutabeadofMill-Pacaround theapplianceadapterandsecurewith3screws (#8x1/2,stainlesssteel). 14)Attachthe45 elbowontothestartercollarby sealingwithMill-Pacsecuringwith3ofthe#8 x1/2"(black)screws. 15)Attach the pipe section to the 45  elbow by sealingwithMill-Pacsecuringwith3ofthe#8 x1/2"screws(black).Pipeseamsshouldbe facingthewall.
  • Page 30: ResidentialAndManufacturedHomes/MobileHomes 3

    installation RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES MINIMUM HORIZONTAL TERMINATION INSTALLATIONS Planning Your Venting Installation See the "Exterior Vent Terminal Locations" YouwillrequirethefollowingcomponentswithyournewHampton DirectVentFreestandingGasStove. ® section for requirements. Pleasereviewyourproducttomakesureyouhaveeverythingyouneed.Intheeventthatyouaremissing anypart,contactyourdealer.DecorativebrassorchrometrimkitsareavailablefromSimpsonDura-Vent Whenplanningyourinstallation,itwillbenecessary fortheirwallthimbles,aswellasasquarewallthimblecover. to select the proper length of vent pipe for your particularrequirements.Determinetheminimum Note: These are the minimum pieces required.
  • Page 31: Dura-VentTerminationKit

    installation DURA-VENT TERMINATION KIT x4or2x6wallconstruction.)Selecttheamount VentTerminalLocations"sectionandinyourlocal Planning Your Dura-Vent of vertical rise desired for "vertical-to-horizontal" buildingcodes. Installation typeinstallations. Todeterminethelengthofventpiperequiredfor TherearetwobasictypesofDura-VentDirectVent Warning: Always maintain required verticalinstallations,measurethedistancefromthe Systeminstallations:horizontalterminationandver- unitflueoutlettotheceiling,theceilingthickness, clearances (air spaces) to nearby ticaltermination.Confirmthemaximumhorizontal theverticalriseinanatticorsecondstorey,and combustibles to prevent a fire hazard. runandmaximumverticalrisefromthediagrams allowforsufficientverticalheightabovetheroofline. inthe"RigidPipeVentingSystems"section....
  • Page 32: HorizontalTerminations

    installation a) Thehorizontalrunofventshouldhavea1/4 Below Grade Snorkel Installation Youwillrequirethefollowingcomponentswithyour inchriseforevery1footofruntowardstheter- If the snorkel termination must be installed newDirectVentFreestandingGasStove.Please mination.Neverallowtheventtorundownward. belowgrade,i.e.basementapplication,proper reviewyourproducttomakesureyouhaveevery- Thiscouldcausehightemperaturesandmay drainage must be provided to prevent water thingyouneed.Intheeventthatyouaremissing presentthepossibilityofafire. fromenteringthesnorkeltermination.Donot anypart,contactyourdealer. attempttoenclosethesnorkelwithinthewall b) The location of the horizontal vent termina- oranyothertypeofenclosure.Seediagram2c.
  • Page 33: VerticalTerminations

    installation c. Before connecting the vent pipe to theventtermination,slidetheblack decorative wall thimble cover over the vent pipe, then slide the Wall PenetrationHeatShieldoverthevent pipe.Dia.3. d. Slide the appliance and vent as- sembly towards the wall carefully insertingtheventpipeintotheriser ventterminalassembly.Itisimportant that the vent pipe extends into the RiserVentBackingPlateasufficient distancesoastoresultinaminimum pipeoverlapof1-1/4inches.Secure...
  • Page 34 installation 7) Ensureventisverticalandsecurethebase oftheflashingtotheroofwithroofingrails, slidestormcollaroverthepipesectionand sealwithamastic. 8) Installtheverticalterminationcapbytwist lockingit. Notes: a) For multistorey vertical installations, a Ceiling Fire stop is required at the Diagram 10: The upper half of the flashing is secondfloor,andanysubsequentfloor. installed under the roofing material and not Diagram 12. The opening should be nailed down until the chimney is installed.
  • Page 35: Converting Class-Ametal Chimney To Direct Vent System

    installation CONVERTING CLASS-A METAL CHIMNEY TO DIRECT VENT SYSTEM Prior to installation and connection of the vent system to a factory-built or masonry chimney, the chimney must be inspected and thoroughly cleaned by a qualified service person, such as a certified chimney sweep or home inspection service.
  • Page 36: CathedralCeilings

    2) Placethesupportintheopening.Loweritto Steeppitchedcathedralceilingsmayrequirethe thecorrectheightasdeterminedbythetable use of a support extension.This piece fits down anddiagrambelow. insidethesupportandcanbeadjustedtoincrease thesupport'slengthbyupto22".Theextensionis H15E-NG11 System Data attachedtothesupportusingtheeightmetalscrews provided.Besurethereisatleasta2inchoverlap For0to4500feetaltitude wheretheextensionjoinsthesupport. Burner Inlet Orifice Sizes:  Max. Input Rating  1 8 , 0 0 0  B t u / h  HIGH ELEVATION Min.
  • Page 37: AerationAdjustment

    installation AERATION GAS PIPE 885 S.I.T. VALVE ADJUSTMENT PRESSURE TESTING DESCRIPTION 1) 6Stageflameadjustment Theappliancemustbeisolatedfromthegassup- Theairshuttercanbeadjustedbymovingtheadjust- 2) Pilotadjustment plypipingsystembyclosingitsindividualmanual ingwireupordown.Thewireisaccessedthrough shut-offvalveduringanypressuretestingofthegas 3) InletPressureTap thebottom.Opentheairshutterforablueflame supplypipingsystemattestpressuresequaltoor 4) OutletPressureTap orcloseforayellowerflame.Theburneraeration lessthan1/2psig.(3.45kPa).Disconnectpiping 5) PilotOutlet isfactorysetbutmayneedadjustingduetoeither 6) MainGasOutlet fromvalveatpressuresover1/2psig. thelocalgassupplyoraltitude. 7) MainGasInlet Themanifoldpressureiscontrolledbyaregulator Minimum Air Shutter Opening: builtintothegascontrol,andshouldbechecked 3/16"...
  • Page 38: ConversionFromNgToLp

    H15E-11 installation CONVERSION FROM NG TO LP CONVERSION FROM NG TO LP THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Unscrew the pilot orifice with the allen key 11. Remove NG stepper motor by removing 2 Each Kit contains one LPG and replace with the LP pilot orifice in the screws in locations shown below. Replace kit and replace pilot cap.
  • Page 39: LogSetInstallation

    installation LOG SET INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the 5) Carefully remove the logs from the unit and diagrams. If the logs are broken do not use the unit unwrap them. The logs are fragile, handle with until they are replaced.
  • Page 40 LOG SET INSTALLATION installation 8) Take the embers and place on the burner in the 9) Place the center cross log on the top of the rear log space between the 2 front logs, ensure not to cover and position as shown below. any burner ports.
  • Page 41: OptionalWallThermostat

    installation OPTIONAL BACK UP BATTERY 5. P ress the ON/OFF button on the hand held remote to code the remote to the IFC–after 4 WALL THERMOSTAT beepsareheard–handheldispairedwithIFC. In the event of a power outage the unit may be operatedbyabackupbatterysystem. Awallthermostatmaybeinstalledifdesired.Con- MANUAL OPERATION nectthewiresasperthewiringdiagrams.
  • Page 42: WiringDiagramWithoutThermostat

    installation WIRING DIAGRAM WITHOUT THERMOSTAT Thisheaterdoesnotrequirea120VA.C.supplyfor WARNING: CAUTION: Ensure that the wires operation.Incaseofapowerfailure,theremote Electrical Grounding do not touch a hot surface and are control/thermostat/ON/OFF switch will continue Instructions away from sharp edges. tooperate. This appliance is equipped with Note: Theoptionalfanandstandardlightsdorequire a three pronged (grounding) 120voltpowerforittooperate. Note:...
  • Page 43: WiringDiagramWithThermostat

    operating instructions WIRING DIAGRAM WITH THERMOSTAT Thermostat( Optional) (Millivolt) RESET SWITCH Hampton®H15E-11DirectVentFreestandingGasStove...
  • Page 44: FirstFire

    operating instructions FIRST FIRE starting/operatingtheappliance,pleasereadthe 5.Stripthermostatwiresandconnectthermostat remotecontroloperatinginstructions(packed wirestogreyswitchwiresandMarrettewiresas with remote control) to understand how to showbelow.(Image4) Thefirstfireinyourstoveispartofthepaintcuring operatethisremotesystem. process.Toensurethatthepaintisproperlycured, itisrecommendedthatyouburnyourfireplacefor OPERATION USING AN OPTIONAL atleastfour(4.hoursthefirsttimeyouuseitwith WALL THERMOSTAT thefanon.Whenfirstoperated,theunitwillrelease an odour caused by the curing of the paint, the AllHamptonstovesshipwithafullfunctionremote burningoffofanyoilsremainingfrommanufacturing. controlasstandardequipment. T hisallowsforbasic Smokedetectorsinthehousemaygooffatthis on/offfunctionaswellastheabilitytooperateas...
  • Page 45: CopyOfTheLightingPlateInstructions

    owner's information COPY OF THE LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING POUR VOTRE SÉCURITÉ – À LIRE AVANT LA MISE EN MARCHE This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1.
  • Page 46: NormalOperatingSoundsOfGasAppliances

    maintenance NORMAL OPERATING SOUNDS OF CLOTHING OR OTHER FLAM- 4) Makeaperiodiccheckofburnerforproperposi- GAS APPLIANCES MABLE MATERIAL SHOULD NOT tionandcondition.Visuallychecktheflameof BE PLACED ON OR NEAR THE theburnerperiodically,makingsuretheflames Itispossiblethatyouwillhearsomesoundsfrom aresteady;notliftingorfloating.Ifthereisa APPLIANCE. yourgasappliance.Thisisperfectlynormaldueto problem,callaqualifiedserviceperson. thefactthattherearevariousgaugesandtypes ofsteelusedwithinyourappliance.Listedbelow 5) Caution: Label all wires prior to disconnec- 9) Periodicallycheckthepilotflames.Correctflame are some examples. All are normal operating tion when servicing controls.
  • Page 47: GeneralVentMaintenance

    maintenance GLASS REPLACEMENT GENERAL VENT FAN MAINTENANCE MAINTENANCE Ifyourfanrequiresmaintenanceorreplacement, 1. T urnoffstoveandallowtoreturntoroomtem- accesstothefanisthroughtherearaccesspanel Conductaninspectionoftheventingsystemsemi- perature. onthebackoftheunit. annually.Recommendedareastoinspectasfollows: 2.Liftoffcasttopandplaceonasoftsurface. IMPORTANT: These fans collect a lot of dust from 1) Checkthe V entingSystemforcorrosioninareas within your home. Ensure you maintain these thatareexposedtotheelements.Thesewill fan motors on a regular basis by vacuuming appearasrustspotsorstreaks,andinextreme out the fan squirrel cages, around the motor, cases, holes. These components should be...
  • Page 48: SafetyScreenReplacement

    maintenance SAFETY SCREEN REPLACEMENT 1.Turnoffstoveandallowtoreturntoroomtemperature. 4. Slidethelightassemblybracketoutoftheway. 2.Liftoffcasttopandplaceonasoftsurface. 5.Loosen4screwsinlocationsshownbelowtoreleasesafetyscreenframe. 6.Slidesafetyscreentoonesidetoremove. 3.Remove2boltsandliftoffcastfront-placefrontcarefullyonasoftsurface. 7.Replacescreenandreversestepstoreinstall. ACCENT LIGHT BULB REPLACEMENT 1.Turnoffstoveandallowtoreturntoroomtemperature. 4. L oosenboltssecuringcastfront–slidelightassemblybracketupwardto release. 2.Shutoffelectricalsupply 5.Removeone(1)screwtoremovebulbhousing. 3.Liftoffcasttopandplaceonasoftsurface. Loosen bolt Remove 1 screw Loosen bolt Lift light assy bracket off bolts to replace bulb Remove one screw in location shown 6.Replacebulb.
  • Page 49: ValveAssemblyReplacement

    maintenance VALVE ASSEMBLY 9. Removebackbracketbyremoving1screw. 13.Liftvalvetrayassemblyupandoutofunitto remove. REPLACEMENT Ifyourvalverequiresmaintenanceorreplacement,  usethefollowinginstructions: Note: Always shut off gas and disconnect electrical supply before removing the valve. 1. Openthefrontpanelandremovethecoverplate byremovingtwoscrews. 10.Removefrontbracketbyremoving2screwsin locationsshownbelow. 14.Replacewithnewvalveassemblyandreverse stepstoreinstall. 2. Disconnectgaslinetostove. 3. Disconnect3/8"NPTpipefrom90 elbowon valveorflexconnector. 11.Remove10screwstoremovevalvetray. 4.  Disconnectthetwo(2)switchwiresfromvalve. 5. LiftofftheCastTopandremovetheCastFront andglassdoor(seedetailedinstructioninthis manual).
  • Page 50: GasMaintenance

    maintenance Gas Maintenance GAS MAINTENANCE - RECOMMENDED ANNUAL ROUTINE Recommended Annual Routine Maintenance for Gas Fireplaces, Stoves and Inserts In order for your Regency appliance to continue to provide comfort to your home periodic maintenance must be performed to ensure it is operating at peak efficiency. The items in the list should be checked by a licensed gas service technician during the annual service check. Your unit may require more frequent maintenance checks if you notice any changes in how it operates. Operational changes to look for can include, but are not limited to, extended start up time, increased fan noise, residue/carbon build up, white build up on the glass/firebox, increased operating noise etc. Should any of these or other conditions arise, discontinue use and schedule a service check with your local licensed gas technician. The list below shows items your licensed service technician will need to check and service at least annually. Clean Inspect Check • Glass • Pilot assembly • Voltage on thermocouple/thermopile (mil- • Interior bricks / panels • Burner livolt models) • Burner ports & burner air shutter •...
  • Page 51: MainAssembly

    parts list MAIN ASSEMBLY Part # Description Part # Description Part # Description 945F FlueCollar/StarterCollar 382-002 FireboxBracketRight 380-007 Doorframe W801015TouchUpPaint-Brown 382-105 Safety Screen Mounting 382-917 FanAssembly(Optional) Bracket(Each)* 5. 383-201 CastFront-Gray 938-337 TouchUpPaint-Cream 380-024 FanDeflector-Right 383-205 CastFront-TimberlineBrown  382-515 RearPanelAssembly 380-023 FanDeflector-Left 383-207 CastFront-Cream...
  • Page 52: Burner&LogAssembly

    parts list BURNER & LOG ASSEMBLY Part # Description 16. 911-084 Valve-NG885SITIPI 16. 911-085 Valve-LP885SITIPI 17. 911-010 StepperMotor-NG 17. 911-011 StepperMotor-LP 18. 911-276 PilotassemblyIPING2Flame 911-277 PilotassemblyIPILP2flame 910-036 NovasitPilotOrifice-NG 910-037 NovasitPilotOrifice-LP 18a. 911-039 NovasitPilotHood2Way 911-137 PilotHoodClip 18b. 911-037 FlameSensor 18c. 911-038 FlameElectrode 19. 904-434...
  • Page 53 notes Hampton®H15E-11DirectVentFreestandingGasStove...
  • Page 54 warranty Limited Lifetime Warranty FPI Fireplace Products International Ltd. (for Canadian customers) and Fireplace Products U.S., Inc. (for U.S. customers) (collectively referred to herein as “FPI”) extends this Limited Lifetime Warranty to the original purchaser of this appliance provided the product remains in the original place of installation. The items covered by this limited warranty and the period of such coverage is set forth in the table below.
  • Page 55 warranty At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty. All warranty claims must be submitted by the dealer servicing the claim, including a copy of the Bill of Sale (proof of purchase by you).
  • Page 56 warranty Limitations of Liability: The original purchaser’s exclusive remedy under this warranty, and FPI’s sole obligation under this warranty, express or implied, in contract or in tort, shall be limited to replacement, repair, or refund, as outlined above. IN NO EVENT WILL FPI BE LIABLE UNDER THIS WARRANTY FOR ANY INCIDENTAL OR CONSEQUENTIAL COMMERCIAL DAMAGES OR DAMAGES TO PROPERTY.
  • Page 57 warranty Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 59 Hampton®H15E-11DirectVentFreestandingGasStove...
  • Page 60 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial #: ____________________________________________________________ H15 Product Video Printed in Canada HamptonisatrademarkofFPIFireplaceProductsInternationalLtd. ©Copyright2021,FPIFireplaceProductsInternationalLtd.Allrightsreserved.