H35 Direct Vent Gas Fireplace
H35 Direct Vent Gas Fireplace
WARNING:
If the information in these instructions are not followed ex-
actly, a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-838
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
MODELS:
H35-NG2 Natural Gas
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.hampton-fi re.com
H35-LP2 Propane
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
Owners &
Installation Manual
07/19/11

Advertisement

Table of Contents
loading

Summary of Contents for HAMPTON BAY Hampton H35-NG2

  • Page 1 Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 918-838 07/19/11 FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4...
  • Page 2 ® HAMPTON Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art Hampton ® Gas Stove by REGENCY FIREPLACE PRODUCTS . The H35-2 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fi replace at the fl...
  • Page 3: Dimensions

    DIMENSIONS UNIT DIMENSIONS * Unit shown with optional side shelves. 38-1/4” (972mm) 26-7/8” (683mm) 16-3/4” (425mm) 15-3/8” (391mm) 26-1/4” (667mm) Hampton® H35-2 Direct Vent Freestanding Gas Stove...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS DIMENSIONS Optional Brick Panel ............35 Log Set Installation ............35 Double DoorRemoval ..........36 Unit Dimensions ............3 Optional side shelves installation ........37 Wiring Diagrams ............38 SAFETY LABEL Wall Thermostat ............39 Remote Control ............39 Copy of Safety Label .............5 OPERATING INSTRUCTIONS REQUIREMENTS Operating Instructions ..........40...
  • Page 5: Safety Label

    Pour utilisation uniquement avec les portes en verre certifi ées avec l'appareil Electrical supply / Électrique 115VAC, 1.13 A, 60Hz. NOT FOR USE WITH SOLID FUELS. / NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE FPI Fireplace Products International Ltd. Delta, BC, Canada Made in Canada/Fabrique au Canada 918-840 For the State of Massachusetts, installation and repair must be done by a plumber or gasfi...
  • Page 6: Requirements

    REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 7: Specifi Cations

    INSTALLATION IMPORTANT MESSAGE INFORMATION FOR SAVE THESE MOBILE / INSTRUCTIONS MANUFACTURED HOMES AFTER FIRST SALE The Direct Vent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. This Hampton ®...
  • Page 8: Before You Start

    INSTALLATION BEFORE YOU START CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED Safe installation and operation of this appliance ON OR NEAR THE APPLIANCE. requires common sense, however, we are required by the Canadian Safety Standards and ANSI Stand- ards to make you aware of the following: INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED...
  • Page 9: General Safety Information

    INSTALLATION GENERAL SAFETY 2) Install Optional Fan. Refer to the "Optional Fan CLEARANCES TO Installation" section. INFORMATION COMBUSTIBLES 3) Set vent restrictors. Refer to the "Vent Restrictor Position" section. 1) The appliance installation must conform with The clearances listed are MINIMUM distances. local Canadian Electrical Code.
  • Page 10: Locating Yourgas Stove

    INSTALLATION OPTIONAL FAN INSTALLATION LOCATING YOUR Fan Kit Contains: GAS STOVE 7) Install locking grommet to power cord and push Qty. Description When selecting a location for your stove, ensure through hole in the rear panel and give a 1/4 Fan Speed Controller with nut, and that the clearances listed above are met as well turn to secure.
  • Page 11: Venting Introduction

    3) Installation of any component part not up the chimney. approved by FPI - Fireplace Products International Ltd. Note: These fl ue pipes must not be connected to any other appliance.
  • Page 12: Exterior Vent Terminal Locations

    INSTALLATION EXTERIOR VENT TERMINAL LOCATIONS Minimum Clearance Requirements Canada Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window Vertical clearance to ventilated soffi t located above the terminal within a horizontal distance of 2 feet (61cm) 22"(56cm) 22"(56cm) from the center line of the terminal (check with the local code)
  • Page 13: 4" X 6-5/8" Rigid Pipe

    INSTALLATION 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART ONLY Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Description Selkirk American Metal Security ICC Excel Simpson Metal-Fab™ ® Direct Temp™...
  • Page 14 Vinyl Siding Standoff for AstroCap Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994). Offset Pipe Selection: Use this table to determine offset pipe lengths.
  • Page 15: Rigid Pipe Venting Systems

    ® The FPI AstroCap and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent Direct Vent Pro, ® American Metal Products Ameri Vent Direct Vent, Security Secure Vent , Selkirk Direct-Temp.
  • Page 16: Elbow For Straight Horizontal Terminations

    INSTALLATION ROTATING 45 ELBOW FOR STRAIGHT HORIZONTAL TERMINATIONS 1) Remove all 4 screws that secure 2) Rotate the elbow 180 the elbow to the unit using a 1/4" 3) Secure the elbow by securing magnetic nut driver. it with the 4 screws. Remove all 4 screws and washers VENTING ARRANGEMENTS...
  • Page 17 #740-952 for LP. Refer to the conver- sion kit to lower BTU rating section for derating instructions. Also, only a snorkel or FPI Riser vent may be Snorkel Termination Riser Vent Termination used as shown in the noted diagrams. No other termination cap is permitted.
  • Page 18 INSTALLATION Horizontal Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option H + H1 With these options, maxi- 3' Min. 2' Max. mum total pipe length is 30 feet with minimum of 8 feet 4' Min. 3' Max.
  • Page 19 INSTALLATION Vertical Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option V V + V1 With these options, max. total pipe length is 30 feet with min. 1' Min. 3' Max. 2' Min. of 6 feet total vertical and max. 2' Min.
  • Page 20: Vertical Termination With Co-Linear Flex System

    INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM Masonry chimneys may take various contours which the fl exible liner will accommodate. However, THE APPLIANCE MUST NOT BE keep the fl exible liner as straight as possible, avoid unnecessary bending. CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL The Air Intake pipe must be attached to the inlet air collar of the termination cap.
  • Page 21: Dv Stove Horizontal Termination Vent Kit

    INSTALLATION DV STOVE HORIZONTAL TERMINATION VENT KIT DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (Part #946-216) includes all the parts needed to install the H35 Direct Vent unit with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown in the "Dura-Vent Termination Kit"...
  • Page 22 INSTALLATION 9) Secure the 4" dia. fl ex liner to the 4" adaptor with Mill-Pac and 3 of the #8 x 1/2" screws (stainless steel). 10) Slide the decorative Thimble Cover over the pipe sections and secure with 4 screws (#8 x 1-1/2"...
  • Page 23: Dura-Vent Termination Kit

    INSTALLATION DURA-VENT TERMINATION KIT Planning Your Dura-Vent important to note the wall thickness. (The wall the vent termination clearance requirements from thimble is suitable for 2 x 4 or 2 x 6 wall construc- decks, windows, soffi ts, gas regulators, air sup- Installation tion.) Select the amount of vertical rise desired for ply inlets and public walkways as specifi...
  • Page 24: Horizontal Installations

    INSTALLATION HORIZONTAL Below Grade Snorkel Installation INSTALLATIONS If the Snorkel Termination must be installed Diagram 1: below grade, i.e. basement application, proper Hint: Apply RIGID VENT SYSTEM drainage must be provided to prevent water silicone to from entering the Snorkel Termination. Refer to female end.
  • Page 25: Vertical Termination

    INSTALLATION Note: 5) Before connecting the horizontal run of vent VERTICAL a) The horizontal run of vent should have pipe to the vent termination, slide the black TERMINATION a 1/4 inch rise for every 1 foot of run decorative wall thimble cover over the vent towards the termination.
  • Page 26 INSTALLATION 7) Ensure vent is vertical and secure the base of the fl ashing to the roof with roofi ng rails, slide storm collar over the pipe section and seal with a mastic. 8) Install the vertical termination cap by twist lock- ing it.
  • Page 27: Converting Chimney To Direct Vent System

    INSTALLATION Approved for US Installations Only CONVERTING 4) Pass the fl ex pipe down through the center of The use of an existing chimney as an air intake is the chimney system, and center the adaptor CLASS-A METAL not covered under the ANSI Z21.88a-2007, CSA on the top of the chimney pipe.
  • Page 28: Cathedral Ceilings

    INSTALLATION Note: Prior to any pressure testing of the gas CATHEDRAL CEILINGS 4) Assemble the desired lengths of Black Pipe supply piping system that exceeds test and Elbows necessary to reach from the ap- pressures of 1/2 psig, this appliance must pliance adaptor up through the support box Round Support (RDS) &...
  • Page 29: Aeration Adjustment

    INSTALLATION AERATION GAS PIPE 5) The pressure check should be carried out ADJUSTMENT PRESSURE TESTING with the unit burning and the setting should be within the limits specifi ed on the safety The burner aeration is factory set but may need ad- The appliance must be isolated from the gas sup- label.
  • Page 30: Conversion From Ng To Lp

    INSTALLATION CONVERSION KIT #791-969 FROM NG TO LP THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Remove the 2 screws holding the Burner Turn control knob to the “OFF” Each Kit contains one LPG Assembly to the fi...
  • Page 31: Installation Of The Dc Sparker

    INSTALLATION 14) Using the Allen wrench as shown in 17) Reverse steps 4) to 2). Attach the DC sparker generator Fig.4, rotate the screw clockwise until connector to the valve with a screw. snug, do not overtighten. 18) Attach clear label "This unit has been converted to LPG"...
  • Page 32 INSTALLATION Attach the Piezo ignition wire to the DC 11) Attach the DC sparker generator wires to Installation of the DC Sparker Sparker. the DC sparker. for the P90 Units Only: Piezo Ignitor Locate the Piezo Ignitor situated at the side of valve.
  • Page 33 INSTALLATION Locate the ground lug at the receptacle Plug the DC spark generator wires to the 12) Mount the heat shield to the DC Sparker. box, left of the unit. DC Sparker. Secure into place with the velcro, which is provided in the kit. 13) Find a location which is not too hot and is easy to reach for changing the battery.
  • Page 34: Conversion Kit To Lower Btu Rating

    INSTALLATION CONVERSION KIT TO LOWER BTU RATING NATURAL GAS - KIT #: 740-950 PROPANE - KIT # 740-952 THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Natural Gas Conversion Kit 740-950 Contains: 5) Unscrew the 2 Rear Log Pins and move to the front hole position.
  • Page 35: Optional Brick Panel

    INSTALLATION 12) Adjust Vent restrictor setting: To set the Vent 4) Before installing the side brick panels, loosen LOG SET restriction as indicated in the diagram, simply the screws for the brick tabs enough so that you INSTALLATION loosen the screws and push the vent restrictor can slide the brick tabs on to the screws easily plate to the correct position.
  • Page 36: Double Doorremoval

    INSTALLATION 4) Place Rear Log A)02-43 on the two pins on 8) Place the Left Top Log D)02-46 on the pin 12) Position notch in Front Right Log G)02-48 on the rear log support. on Log B)02-56 and on top of the cutout Log F)02-47 and push the bottom right edge on Log A)02-43.
  • Page 37: Optional Side Shelves Installation

    INSTALLATION OPTIONAL SIDE SHELVES INSTALLATION 1) Lift off the Cast Top. 3) Flip assembled shelf over - line up the bracket on the unit as shown below. Note: Orient the shelf so the support bracket is to the front of the unit.
  • Page 38: Wiring Diagrams

    INSTALLATION WIRING DIAGRAMS If any of the original wires as supplied with the Caution: Ensure that the wires do WARNING: Electrical Grounding appliance must be replaced, it must be replaced not touch any hot surfaces and are Instructions with CSA type SEW (200 C) or its equivalent.
  • Page 39: Wall Thermostat

    INSTALLATION PROPANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual. CAUTION WALL THERMOSTAT Do not connect the millivolt wall thermostat wires A wall thermostat may be installed if desired. to the 120V wires.
  • Page 40: Operating Instructions

    OPERATING INSTRUCTIONS seen when lighting the unit - the logs have 4) When the pilot stays lit, turn the gas knob further 2) Connect the wires as per the wiring diagram been incorrectly positioned. counterclockwise to the "ON" position. below. 5) Use the thermostat or remote control to turn on 7) The unit should never be turned off, and on CAUTION...
  • Page 41: Copy Of The Lighting Plate Instructions

    OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: A S5601-2004, New Zealand: NZS 5261) WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, or additional information consult a qualified installer, service agency or gas supplier.
  • Page 42: Normal Operating Sounds Of Gas Appliances

    MAINTENANCE NORMAL OPERATING 2) Clean glass (never when unit is hot), appliance, CLOTHING OR OTHER FLAMMA- and door with a damp cloth. Never use an BLE MATERIAL SHOULD NOT BE SOUNDS OF abrasive cleaner. PLACED ON OR NEAR THE APPLI- GAS APPLIANCES 3) The heater is fi...
  • Page 43: General Vent Maintenance

    MAINTENANCE 2) Open the 2 latches of the Glass Front. FAN MAINTENANCE GENERAL VENT MAINTENANCE 3) Lift the Glass Front Assembly up. If your fan requires maintenance or replacement, access to the fan is through the rear access panel Conduct an inspection of the venting system semi- on the back of the unit.
  • Page 44: Removing Valve

    MAINTENANCE 3) Disconnect gas line to stove. 11) Carefully lift the burner tray assembly out. 4) Disconnect 3/8" NPT pipe from 90 elbow on valve. 5) Disconnect the two (2) switch wires from valve. 6) Disconnect piezo wire. Replacing the Fan: Reverse the above steps (1 - 4).
  • Page 45: Main Assembly

    PARTS LIST MAIN ASSEMBLY Part # Description Description Description Part # Part # 918-518 Manual 740-20** Casting - Top 945F Direct Vent Adaptor 740-21** Casting - Left Side *Note: Not available as a replacement part. 740-22** Casting - Right Side Rear Panel Assembly 740-23** Casting - Front...
  • Page 46: Burner & Log Assembly

    PARTS LIST BURNER & LOG ASSEMBLY Description Part # 740-574/P Valve Assembly S.I.T. - Natural Gas 740-576/P Valve Assembly S.I.T. - Propane 910-478 Valve S.I.T. - NG/LP 904-689 #33 Orifi ce - N.G. 904-645 #51 Orifi ce - LP 910-190 Piezo Ignitor &...
  • Page 47: Warranty

    At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufac- tured. ie. as products evolve, fi eld modifi cations or upgrades will not be performed.
  • Page 48 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Hampton is a trademark of FPI Fireplace Products International Ltd. © Copyright 2010, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

H35-lp2H35