RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES

MINIMUM HORIZONTAL TERMINATION INSTALLATIONS

Planning Your Venting Installation
See the "Exterior Vent Terminal Locations"
section for requirements.
When planning your installation, it will be necessary
to select the proper length of vent pipe for your
particular requirements. Determine the minimum
clearance to combustibles from the rear of the unit
to the wall. It is also important to note the wall thick-
ness. Before cutting the vent hole through the wall
ensure that ALL vent and termination clearances
(Refer to the "Exterior Vent Terminal Locations"
section) will be met.
*If this is an outside corner, the minimum distance
between the vent and the outside corner is 6"
(15cm). See "F" on the diagram in the "Exterior
Vent Terminal Locations" section.
NOTE: Ensure compliance with the outside vent
terminal location before cutting hole as both dimen-
sions must be met.
Hampton® H15-1 Direct Vent Freestanding Gas Stove
You will require the following components with your new Hampton
Stove. Please review your product to make sure you have everything you need. In the event that you are
missing any part, contact your dealer. Decorative brass or chrome trim kits are available from Simpson
Dura-Vent for their wall thimbles, as well as a square wall thimble cover.
Note: These are the minimum pieces required. Other parts may be required for your particular
installation.
Kit #640-944
Minimum components for a Horizontal Installation:
640-944
Horizontal Termination Kit which includes:
1
6-5/8" Dia. x 18" Black Pipe
1
4" Dia. x 18"
1
946-202
1
640-530/P
1
640-545/P
1
948-128
380-946
Horizontal Termination Kit which includes:
1
6-5/8" Dia. x 12" Black Pipe
1
4" Dia. x 12"
1
946-202
1
946-523/P
1
640-545/P
1
948-128
Optional Components:
946-204
45
o
Elbow - 6-5/8" Black pipe
and 4" Aluminum Vent
946-205
Vinyl Siding Shield for Riser Vent
Terminal
946-208/P
Vent Guard (Riser Vent Terminal)
Square Wall Thimble Cover*
Snorkel Termination (36")
Snorkel Termination (14")
Wall Penetration
Heat Shield*
* Simpson Dura-Vent Components
Kit #380-946
Aluminum Vent
Wall Penetration Heat Shield (Wall Thimble) (2 pcs)
Riser Vent Terminal
Decorative Wall Trim (Black)
Tube Mill-Pac Screws
Aluminum Vent
Wall Penetration Heat Shield (Wall Thimble) (2 pcs)
AstroCap
Decorative Wall Trim (Black)
Tube Mill-Pac Screws
946-523/P
946-206
946-506/P
INSTALLATION
®
Direct Vent Freestanding Gas
AstroCap
Vinyl Siding Standoff (AstroCap)
Vent Guard (AstroCap)