Safety Label; Copy Of Safety Label - HAMPTON BAY Hampton H27-NG Owners & Installation Manual

Direct vent gas fireplace
Hide thumbs Also See for Hampton H27-NG:
Table of Contents

Advertisement

SAFETY LABEL

This is a copy of the label that accompanies
each Direct Vent Freestanding Gas Stove.
We have printed a copy of the contents here
for your review.
WN# 16378
Tested to: Gas-Fired Appliances For Use At High
Altitudes CGA 2-17-M91,
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
FACTORY EQUIPPED FOR NATURAL GAS
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifice size
Altitude
FACTORY EQUIPPED FOR PROPANE GAS
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifice size
Altitude
Minimum Clearances to Combustibles/Degagement Minimum De Materiaux Combustibles
Minimum ceiling height from top of unit:
Minimum plafond hauteur en haut de
l'appareil: 24"/610mm
A 6"/150mm
B 3"/75mm
Minimum clearance of Vent Terminal
to Outside Corner & Inside Corner:
with AstroCap 6"/150mm
with Dura-Vent Cap 12"/300mm
VENTED GAS FIREPLACE HEATER: This appliance must be installed in accordance with local codes, if any; if none,
follow:the national Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.Electrical
Supply (115 V, 1.13A, 60 Hz). This vented gas fireplace heater is not for use with filters.
FOYER AU GAZ À ÈVACUATION
r glements, selon les codes installation ANS Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
è
électrique. Ne doit pas être utilisé avec un combustible solide.
FPI Fireplace Products International Ltd. Delta, BC, Canada
Made in Canada/Fabrique au Canada
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the
Commonwealth of Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720
and a CO alarm with battery back up in the same room where the gas appliance is installed.
4
NOTE: Hampton
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.

COPY OF SAFETY LABEL

Listed:
VENTED GAS FIREPLACE HEATER
Certified for/Certifi e pour:
é
CANADA and U.S.A.
Vented Gas Fireplace Heaters
5"
WC/C.E. (1.25 kPa)
3.8" WC/C.E. (0.94 kPa)
1.1" WC/C.E. (0.27 kPa)
25,000 Btu/h (7.32 Kw/h)
12,500 Btu/h (3.66 Kw/h)
#42 DMS
0-4500 ft/pi (0-1372m)
12"
WC/C.E. (3.00 kPa)
11" WC/C.E.
2.9" WC/C.E. (0.72 kPa)
23,000 Btu/h (6.74 Kw/h)
11,500 Btu/h (3.37 Kw/h)
#54 DMS
0-4500 ft/pi (0-1372m)
24"/610
mm
C 2" / 50mm
E 2"/50mm
: Installer l`appareil selon les codes ou reglements locaux, ou, en l`absence de tels
d'
I
®
units are constantly being
DUPLICATE SERIAL NO.
ANSI Z21.88a-2007/CSA 2.33a-2007
Model:H27-NG
É
QUIP A L'UISINE POUR GAZ NATURAL
É
Pression d'allimentation minimum
Pression la tubulure d' chappement lev e
à
Pression la tubulure d' chappement basse
à
D bit Calorifique maximum
é
D bit Calorifique minimum
é
Dimensions de l'orifice
(2.37mm)
L'altitude
É
QUIP A L'UISINE POUR GAZ PROPANE
É
Model:H27-LP
Pression d'allimentation minimum
(2.74 kPa)
Pression la tubulure d' chappement lev e
à
Pression la tubulure d' chappement basse
à
D bit Calorifique maximum
é
D bit Calorifique minimum
é
(1.4mm)
Dimensions de l'orifice
L'altitude
Left Side Wall
Left Side Wall
A
B
Vertical
Horizontal
Pipe
Pipe
A
Right Side Wall
Right Side Wall
351
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
351
Serial No./ No de serie
é
é
é
é
é
é
See Manual for details
A
E
C
E
Not for use with solid fuels.
Alimentation
918-813
®
Hampton
H27 Direct Vent Freestanding Gas Stove
é
é

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H27-lpH27

Table of Contents