In the iSCSI Configuration page, enter values for one of the data ports.
NOTE:
• By default, the wizard recommends configuring Data Port SA0. HP recommends
accepting the default.
• Assign an IP Address to the data port.
• VLANs are set up on the switch and are used as one method of controlling access to the
storage. If using VLANs, enter the VLAN ID to use (0 = not used).
• The wizard suggests a default iSCSI Target Name and iSCSI Target Alias. Accept
the default or enter user-defined values.
• Be sure to enter the iSCSI Initiator Name exactly as assigned in the iSCSI initiator
software utility (on the server). Include all special characters, including periods and
spaces. If the Initiator Name is entered incorrectly, the target cannot be presented
to the initiator.
• In dual-controller configurations, the Redundant iSCSI Configuration page is displayed,
to enter settings for a data port on the redundant module.
• To configure the remaining data ports, complete the Initial System Configuration Wizard
process, and then use tasks available in the Configure tab. (For more information, see
"Configuring management and data
72
Wizards
ports" on page 33.)