Setting The Preferred Path For A Lun (Preferred Path); Viewing Detailed Component Information (More Information) - HP StorageWorks 1510i - Modular Smart Array User Manual

Active/active firmware v2.x
Hide thumbs Also See for StorageWorks 1510i - Modular Smart Array:
Table of Contents

Advertisement

Setting the preferred path for a LUN (Preferred Path)

NOTE:
This task is available for dual-controller configurations only.
To manually (explicitly) set controller ownership of a LUN:
1.
Select an already-configured logical drive from the system component list, and then select the
Preferred Path task.
2.
Expand the Preferred Path drop-down box and select a controller.
IMPORTANT:
If the Redundancy Setting mode is set to "Automatic", path ownership may automatically switch
from one controller to the other, depending on the processing load, as the system attempts
to balance the processing load between the two controllers. To permanently set the path for
a LUN, the Redundancy Setting mode must be set to 'Manual". For more information, see
"Disabling auto-path switching (Redundancy

Viewing detailed component information (More Information)

To view detailed information about a system component, select the desired component, and then select
More Information. The following image illustrates sample information displayed for a target.
Settings)" on page 64.
HP Storage Management Utility user guide
67