PLC-XL51 Expand Serial Command Functional Specifications
9.11 Setting Status Read Command
9.11.1 CR_LANG Command
Command
"CR_LANG"[CR]
Details
Get selected language
Acceptable
Response
%a
Unacceptable
9.11.2 CR_ZOOM Command
Command
"CR_ZOOM"[CR]
Details
Get Zoom store mode setting status
Acceptable
Response
%a
Unacceptable
9.11.3 CR_UNIFORMITY Command
Command
"CR_UNIFORMITY"[CR]
Details
Get Uniformity store mode setting status
Acceptable
Response
%a
Unacceptable
9.11.4 CR_AUTOSETUPPCADJ Command
Command
"CR_AUTOSETUPPCADJ" [CR]
Details
Get Auto PC adj. setting status in Auto setup
Acceptable
Response
%a
Unacceptable
"000_%a"[CR]
"ENG" -------------------------- English is selected
"DEU" -------------------------- German is selected
"FRA" -------------------------- French is selected
"ITA" --------------------------- Italian is selected
"ESP" -------------------------- Spanish is selected
"POR" -------------------------- Portuguese is selected
"NED" -------------------------- Dutch is selected
"SVE" -------------------------- Swedish is selected
"JPN" -------------------------- Japanese is selected
"CHI" -------------------------- Chinese is selected
"KOR" -------------------------- Korean is selected
"RUS" -------------------------- Russian is selected
"FIN" ---------------------------- Finnish is selected
"POL" --------------------------- Polish is selected
"HUN" -------------------------- Hungarian is selected
"ROM" -------------------------- Romanian is selected
"?"[CR]
"000_%a"[CR]
"RST" --------------------------- "Reset" is selected
"STR1" -------------------------- "Store1" is selected
"STR2" -------------------------- "Store 2" is selected
"?"[CR]
"000_%a"[CR]
"RST" --------------------------- "Reset" is selected
"STR1" -------------------------- "Store1" is selected
"STR2" -------------------------- "Store 2" is selected
"?"[CR]
"000_%a"[CR]
"ON" ------------------ Auto PC ADJ. in Auto setup is ON
"OFF" ----------------- Auto PC ADJ. in Auto setup is OFF
"?"[CR]
54/63