PLC-XL51 Expand Serial Command Functional Specifications
8.10.6 CF_LOGO Command
Command
"CF_LOGO_%1_%2"[CR]
%1
"0000"-"9999" ----------------- Set LOGO PIN CODE directly
"OFF" ---------------------------- Disable Logo function
"DFLT" --------------------------- Display Default Logo
"USER" -------------------------- Display Captured Logo
"UP" --------------- Switch Logo setting forward
%2
"DN" --------------- Switch Logo setting backward
Set / Cancel Logo
The value set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF
This command is available in normal Power ON status.
%1--- Set LOGO PIN CODE
- When LOGO LOCK is in operation
PIN CODE is correct ------------------ Command is valid (Acceptable)
PIN CODE is incorrect ---------------- Command is invalid (Error Code "102")
Details
PIN CODE is out of %1 range ------ Command is invalid (Error Code "? ")
-When LOGO LOCK is not in operation
PIN CODE is within %1 range ------ Command is valid
PIN CODE is out of %1 range ------ Command is invalid (Error Code "? ")
Note) Receiving correct LOGO PIN CODE while LOGO LOCK is in operation
enables to change LOGO setting, but it does not release LOGO LOCK. (LOGO
LOCK continues.)
Projector returns Error Code "101" by receiving USER in %2 when capture has
not operated.
Acceptable
Response
Unacceptable
8.10.7 CF_CEIL Command
Command
"CF_CEIL_%1"[CR]
"ON" ------------------------ Set Ceiling to ON
%1
"OFF" ----------------------- Set Ceiling to OFF
Set/Cancel Ceiling setting.
The value set by this command is stored in EEPROM and its setting is effective
Details
even after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.10.8 CF_REAR Command
Command
"CF_REAR_%1"[CR]
"ON" --------------------------- Set Rear to ON
%1
"OFF" ------------------------- Set Rear to OFF
Set/Cancel Rear setting.
When Rear is ON, image is left/right reversed.
Details
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
(OFF → DFLT → User → OFF → 0û 0 û )
(OFF → User → DFLT → OFF → 0û 0 û )
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
31/63