Cf_Bback Command; Cf_Disp Command - Sanyo PLC-XL51 - 2700 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XL51 - 2700 Lumens:
Table of Contents

Advertisement

PLC-XL51 Expand Serial Command Functional Specifications

8.10.4 CF_BBACK Command

Command
"CF_BBACK_%1"[CR]
"ON" ----------------------------- Select Blue Back
"OFF" ---------------------------- Cancel Blue Back
"UP" ------------------------------ Switch setting (On → Off → On → ÿ e ÿ e ÿ e )
%1
"DN" ------------------------------ Switch setting (On → Off → On → ÿ e ÿ e ÿ e )
Note) "UP" and "DN" behave the same.
Set / Cancel Blue Back
The value set by this command is stored in EEPROM and its setting is effective
Details
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable

8.10.5 CF_DISP Command

Command
"CF_DISP_%1"[CR]
"ON" ----------------------------- Select Display
"OFF" --------------------------- Cancel Display
"CNTDWNOFF" -------------- Count down OFF
"UP" --------------- Switch Display mode forward
%1
"DN" --------------- Switch Display mode backward
Set / Cancel Display
The value set by this command is stored in EEPROM and its setting is effective
Details
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
ÿ On → Countdown OFF → Off → On → 0û 0 û ÿ
ÿ On → Off → Countdown OFF → On → 0û 0 û ÿ
"000"[CR]
"Error Code"[CR]