PLC-XL51 Expand Serial Command Functional Specifications
9.4 Image Status Read Command
9.4.1
CR_BRIGHT Command
Command
"CR_BRIGHT"[CR]
Details
Get Brightness value of user control
Acceptable
Response
%a
Unacceptable
9.4.2
CR_CONT Command
Command
"CR_CONT"[CR]
Details
Get Contrast value of user control
Acceptable
Response
%a
Unacceptable
9.4.3
CR_COLOR Command
Command
"CR_COLOR"[CR]
Details
Get Color value of user control
Acceptable
Response
%a
Unacceptable
9.4.4
CR_TINT Command
Command
"CR_TINT"[CR]
Details
Get Tint value of user control
Acceptable
%a
Response
Unacceptable
9.4.5
CR_SHARP Command
Command
"CR_SHARP"[CR]
Details
Get Sharpness value of user control
Acceptable
Response
%a
Unacceptable
"000_ÿ ÿ A
"[CR]
"000"~"063"
"?"[CR]
"000_ÿ ÿ A
"[CR]
"000"~"063"
"?"[CR]
"000_%a"[CR]
"000"~"063"
"?"[CR]
"000_%a"[CR]
"000"~"063"
"Error Code"[CR] ----- When the command is invalid due to
condition such as Input source
"?"[CR] --------------------- When unclear command is received
"000_%a"[CR]
"000"~"015"
"?"[CR]
40/63