Cf_Keystone Command; Cf_Kystnmode Command - Sanyo PLC-XL51 - 2700 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XL51 - 2700 Lumens:
Table of Contents

Advertisement

PLC-XL51 Expand Serial Command Functional Specifications
8.7.3

CF_KEYSTONE Command

Command
"CF_KEYSTONE_%1"[CR]
"UP" ------------- Correct Keystone distortion to reduce upper part of image
"FUP" ----------- Correct Keystone distortion to reduce upper part by 2steps
%1
"DN" ------------- Correct Keystone distortion to reduce lower part of image
"FDN" ----------- Correct Keystone distortion to reduce lower part by 2steps
"RST" ------------ Set Keystone OFF
Change Keystone distortion correction
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.7.4

CF_KYSTNMODE Command

Command
"CF_KYSTNMODE_%1"[CR]
"STR" --------- Set Keystone store mode to Store
%1
"RST" --------- Set Keystone store mode to Reset
Set Keystone store mode
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"201"[CR] ----When reaching the Keystone correction limit or
reaching 1 step to correction limit and "FDN"/"FUP"
is received.
(The command is not executed)
"000"[CR]
"Error Code"[CR]
26/63